METIEC MT1100 Operation And Installation Manual Download Page 4

 

 
 

 

A1-MT1100 

1

 

Overview 

1.1

 

Operation Instructions of Manual

 

1.1.1

 

It  is  not  allowed  to  print  or  disclose  any  content  of  this  Manual,  including  pictures  and  audio 

products, under any name without the consent of Huchuang Union; 

1.1.2

 

The equipment operator may copy some sections of this Operation Manual for internal use only, 

such as for instructing the user how to deal with emergencies. These sections are clearly listed in 

the catalogue of this manual; 

1.1.3

 

Wuhan Huchuang Union Technology Co., Ltd. reserves the copyright of the Manual. The manual 

contains  the  information  protected  by  copyright  laws.  No  part  of  the  Manual  is  allowed  to  be 

copied and sent to the users without the prior written permission of the copyright holder; 

1.1.4

 

The contents of the Manual are subject to change without prior notice. 

 

1.2

 

Overview

 

 

As a data transmitter and transmitter host monitored by the laboratory, MT1100 can receive local 

wireless data and transmit the data to the cloud server via 4G. In addition, MT1100 also has WIFI function, 

and can transmit the received wireless data to the local server through WIFI after being connected to the 

specified WIFI, and is suitable for local networking. Besides, MT1100 can be connected to MT500 devices, 

eight MT500 devices at most; 

 

MT1100  is  equipped  with  a  rechargeable  lithium  battery  and  can  give  power  failure  alarm  and 

continue to run for more than 8 hours after the adapter is disconnected with the power supply. 

1.3

 

Environmental Requirements

 

1.3.1

 

Only for indoor use, no high temperature, moisture, water or dust; 

1.3.2

 

Atmospheric pressure: 70kPa

105kPa; Working ambient temperature: 0

℃~

+50

Summary of Contents for MT1100

Page 1: ...HCLH SOP YF 072 115 Data Transceiver and Power Monitoring Series MT1100 Operation and Installation Manual...

Page 2: ...roduction Address No 1 Workshop 1F Building B10 Wuhan Hi Tech Medical Device Park No 818 Gaoxin Avenue East Lake Hi Tech Development Zone Wuhan Hubei China After Sales Service Unit Wuhan Huchuang Unio...

Page 3: ...1 Structure Features 5 2 2 Equipment Parameters 8 3 Basic Operation Instructions 9 3 1 Installation Method 9 3 1 1 Laid Flat 9 3 1 2 Wall Mounting 9 3 2 Power On for Use 10 3 3 Main Interface Instruct...

Page 4: ...the copyright holder 1 1 4 The contents of the Manual are subject to change without prior notice 1 2 Overview As a data transmitter and transmitter host monitored by the laboratory MT1100 can receive...

Page 5: ...after being cleaned and sterilized 1 4 2 During recycling and handling MT1100 device it is recommended that the company s technical personnel dismantle it and recycle it according to different waste...

Page 6: ...nd Equipment Parameters 2 1 Structure Features a Data Display Screen Displays the current states and the current received data of the device b Keys Push type buttons set or modify the equipment parame...

Page 7: ...A1 MT1100 6 c d e f g i j k h l...

Page 8: ...art the equipment the factory setting shall not be reset when the equipment breaks down e Power toggle switch The device can be powered ON normally only when the toggle switch is turned to ON position...

Page 9: ...eal time Adapter power failure detection Uploads the power failure status at once Local alarm mode Audible and visual alarm Display screen 2 42 inches OLED Battery endurance 8 hours the power supply i...

Page 10: ...shown in the following figure Note Try to keep the antenna away from metal objects otherwise the transmission of wireless signals will be affected 3 1 2 Wall Mounting Select a relatively open smooth...

Page 11: ...onnected with MT500 the IP address of the device shall be set in advance and then it shall be connected with MT500 through a crossover network cable 3 3 Main Interface Instructions Key 1 UP key Key 2...

Page 12: ...that the device is connected to the WIFI successfully err means that the device is connected to the local server abnormally Number of TCP clients successfully connected number of MT500 devices 8 at m...

Page 13: ...f Buttons Key 1 The system returns to the main interface when the key is pressed Key 2 The system returns to the main interface when the key is pressed Key 3 The system returns to the main interface w...

Page 14: ...to add the current set value by 1 Key 2 key Press this button to reduce the current set value by 1 Key 3 key When you press the button the cursor will move to the next set value Key 4 OK key When you...

Page 15: ...y Press this button to reduce the current set value by 1 the key can be pressed and held Key 3 key When you press the button the cursor will move to the next set value Key 4 OK key When you press the...

Page 16: ...nd letters 14 bits at most insufficient ones replaced by Operation Instructions of Buttons Key 1 key Press this button to add the set value Key 2 key Press this button to reduce the set value Key 3 ke...

Page 17: ...arameters but directly returns to the setting interface 4 Precautions The local wireless transmission distance of MT1100 is limited and should generally not exceed 3 rooms If the walls of the rooms ar...

Page 18: ...provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordan...

Page 19: ...uirements use accessories that maintain a 10mm separation distance between the user s body and the back of the handset The use of belt clips holsters and similar accessories should not contain metalli...

Page 20: ...A1 MT1100 19 Wuhan Huchuang United Technology Co Ltd Address No 1 Workshop 1F Building B10 Wuhan Hi Tech Medical Device Park No 818 Gaoxin Avenue East Lake Hi Tech Development Zone Wuhan Hubei China...