A1-MT1100 

1.3.3

 

Storage ambient temperature: 0

℃~

+50

; relative humidity in the working environment: ≤80% 

(non-condensing); 

1.3.4

 

Power adapter (input: AC100V ~ 240V, 50/60Hz; output: 5V, 2.1A, 10.5W); 

1.4

 

Environmental Protection Instructions

 

1.4.1

 

MT1100 device contains reusable materials, and its components can be recycled after being cleaned 

and sterilized. 

1.4.2

 

During  recycling  and  handling  MT1100  device,  it  is  recommended  that  the  company's  technical 

personnel dismantle it and recycle it according to different waste groups; 

1.4.3

 

According  to  national  regulations,  the  compositions  of  the  main  raw  materials  of  MT1100 

equipment shall be are shown in (Table 1). 

Table 1 Compositions of Main Raw Materials of MT1100 

Name 

Composition 

Casing 

ABS+PC

 

Baseplate 

Sheet metal

 

Battery 

Lithium battery

 

PCB 

Including electrical components

 

 

 

 

Summary of Contents for MT1100

Page 1: ...HCLH SOP YF 072 115 Data Transceiver and Power Monitoring Series MT1100 Operation and Installation Manual...

Page 2: ...roduction Address No 1 Workshop 1F Building B10 Wuhan Hi Tech Medical Device Park No 818 Gaoxin Avenue East Lake Hi Tech Development Zone Wuhan Hubei China After Sales Service Unit Wuhan Huchuang Unio...

Page 3: ...1 Structure Features 5 2 2 Equipment Parameters 8 3 Basic Operation Instructions 9 3 1 Installation Method 9 3 1 1 Laid Flat 9 3 1 2 Wall Mounting 9 3 2 Power On for Use 10 3 3 Main Interface Instruct...

Page 4: ...the copyright holder 1 1 4 The contents of the Manual are subject to change without prior notice 1 2 Overview As a data transmitter and transmitter host monitored by the laboratory MT1100 can receive...

Page 5: ...after being cleaned and sterilized 1 4 2 During recycling and handling MT1100 device it is recommended that the company s technical personnel dismantle it and recycle it according to different waste...

Page 6: ...nd Equipment Parameters 2 1 Structure Features a Data Display Screen Displays the current states and the current received data of the device b Keys Push type buttons set or modify the equipment parame...

Page 7: ...A1 MT1100 6 c d e f g i j k h l...

Page 8: ...art the equipment the factory setting shall not be reset when the equipment breaks down e Power toggle switch The device can be powered ON normally only when the toggle switch is turned to ON position...

Page 9: ...eal time Adapter power failure detection Uploads the power failure status at once Local alarm mode Audible and visual alarm Display screen 2 42 inches OLED Battery endurance 8 hours the power supply i...

Page 10: ...shown in the following figure Note Try to keep the antenna away from metal objects otherwise the transmission of wireless signals will be affected 3 1 2 Wall Mounting Select a relatively open smooth...

Page 11: ...onnected with MT500 the IP address of the device shall be set in advance and then it shall be connected with MT500 through a crossover network cable 3 3 Main Interface Instructions Key 1 UP key Key 2...

Page 12: ...that the device is connected to the WIFI successfully err means that the device is connected to the local server abnormally Number of TCP clients successfully connected number of MT500 devices 8 at m...

Page 13: ...f Buttons Key 1 The system returns to the main interface when the key is pressed Key 2 The system returns to the main interface when the key is pressed Key 3 The system returns to the main interface w...

Page 14: ...to add the current set value by 1 Key 2 key Press this button to reduce the current set value by 1 Key 3 key When you press the button the cursor will move to the next set value Key 4 OK key When you...

Page 15: ...y Press this button to reduce the current set value by 1 the key can be pressed and held Key 3 key When you press the button the cursor will move to the next set value Key 4 OK key When you press the...

Page 16: ...nd letters 14 bits at most insufficient ones replaced by Operation Instructions of Buttons Key 1 key Press this button to add the set value Key 2 key Press this button to reduce the set value Key 3 ke...

Page 17: ...arameters but directly returns to the setting interface 4 Precautions The local wireless transmission distance of MT1100 is limited and should generally not exceed 3 rooms If the walls of the rooms ar...

Page 18: ...provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordan...

Page 19: ...uirements use accessories that maintain a 10mm separation distance between the user s body and the back of the handset The use of belt clips holsters and similar accessories should not contain metalli...

Page 20: ...A1 MT1100 19 Wuhan Huchuang United Technology Co Ltd Address No 1 Workshop 1F Building B10 Wuhan Hi Tech Medical Device Park No 818 Gaoxin Avenue East Lake Hi Tech Development Zone Wuhan Hubei China...

Reviews: