8. INSTALLING THE REGTRONIC IN AN IO-LINK NETWORK
8.1 Example of TIA Portal configuration
The IO-Link Regtronic controls the pressure, using 2 output bytes and 2 input bytes.
S7 PCT configuration
Upload the IODD Regtronic IODD file to the catalogue. Select the 02282REGTRONIC file and install it in the designated port.
Configuration of unit parameters
In addition to the display-configurable parameters, two more parameters are available:
- Target safe condition – sets the status of the regulator in the event of communication failure with the Master (with power supply on).
0 Target = the pressure remains set to the last value
1 Target = the pressure is set to 0.
- Data storage