9. TECHNICAL DATA
9.1 IO-Link ELECTRICAL CONNECTION
TECHNICAL DATA
Fieldbus
IO-Link version 1.1
Communication speed
Kbps
230.4 (COM3)
Vendor ID / Device ID
1046 (hex 0x0416) / 32 (hex 0x000020)
Minimum cycle time
ms
2.8
Process data length
2 byte of Input / 2 byte of Output
Supply voltage range
VDC
from 18 to 30
Maximum admissible voltage
VDC
32 *
Protection
Module protected from overload and polarity inversion. Outputs protected from overloads and short-circuits.
Connections
Fieldbus: M12 male, A-coded - Port Class A.
Diagnostics
IO-Link: via local LED lights and software messages.
Power supply current absorption
Max 150 mA to 18 V
* IIMPORTANT! Voltage greater than 32VDC will damage the system irreparably.
TECHNICAL DATA
REGTRONIC
REGTRONIC
NEW DEAL
REGTRONIC
300
REGTRONIC
400
Threaded port
M5
1/8’’
1/4’’
3/4’’
1’’
1/2’’
3/4’’
1’’
1’’
1 1/4’’ 1 1/2’’
2’’
Fluid
Filtered, unlubricated air. The air must be filtered at least 10 µm
MIN inlet pressure
bar
Regulation pr 1 bar
MAX inlet pressure
bar
11
Temperature range
°C
from 0 to 50
Pressure regulation range
bar
from 0.05 to 10 (settable full scale and minimum pressure)
Flow rate at 6.3 bar ∆P 0.5
Nl/min
10
1300
1500
10000
4500
18000
20000
Flow rate at 6.3 bar ∆P 1
Nl/min
10
1450
1700
13000
7000
-
-
Exhaust flow rate at 6.3 bar with 0.1 bar overpressure
Nl/min
2
600
1300
1800
250
400
400
Exhaust flow rate at 6.3 bar with 0.5 bar overpressure
Nl/min
9
1000
1500
2000
500
850
850
Weight
kg
0.2
0.38
0.38
1.3
1.5
5
5.8
Class of protection
IP 65
Linearity
≤ ± 0.5% (Full scale)
Hysteresis
≤ ± 0.2% (Full scale)
Repeatability
≤ ± 0.2% (Full scale)
Sensitivity/Dead-band
setting range 10 to 300 mbar
Output pressure (display version)
Accuracy
≤ ± 0.3% (Full scale)
Unit of measurement
bar, MPa, psi
Minimum resolution
0.01 bar - 0.001 MPa - 0.01 psi
Temperature characteristics
max 2 mbar / °C
Response time with ∆P =1 bar
volume 100 cc
volume 1000 cc
from 6 to 7 bar
s
0.5
0.2
0.3
0.45
0.35
from 7 to 6 bar
s 0.55
0.3
0.3
0.45
0.7
Installation position
In any position
Notes
The features shown refer to the static condition only. With air consumption on the output side, the pressure may vary.
Summary of Contents for REGTRONIC IO-Link
Page 1: ...REGTRONIC IO Link MANUALE D USO REGTRONIC IO Link USER MANUAL...
Page 15: ...15 NOTE Esempio di visualizzazione in Siemens S7 PCT...
Page 16: ...16 NOTES...
Page 30: ...30 NOTES Example of display in Siemens S7 PCT...
Page 31: ...31 NOTES...
Page 32: ...32 www metalwork eu M0030212 IT_EN IM00_01 2020 NOTES...