21
4.2.5 SPEED REGULATION CONTROL
Can be used to change the regulator response speed
4.2.6 ZERO SETTING (TEMPERATURE COMPENSATION)
The instrument is calibrated at an ambient temperature of 20°C. The pressure value measured by the internal transducer can vary with the
ambient temperature and it may be necessary to reset the reading.
The value read can be reset through the reset function.
The function is only active if the pressure displayed is less than 150 mbar.
Upon zero resetting, the temperature compensation activates and the consequent change in pressure is automatically compensated.
CAUTION
: the resetting has an effect on the calibration of the instrument. Before making it, make sure the supply pressure has been
removed and the output circuit is disconnected.
V = 10 fast adjustment
V = 1 low adjustment
4.3 DEBUG
Utility used for checking correct operation of the two solenoid valves.
• Select
DEBUG
and press OK.
• Select
PIN
and press OK. The in solenoid valve activates and the pressure
increases.
• Press OK. The in solenoid valve deactivates and pressure stabilizes.
• Select
POUT
and press OK. The out solenoid valve activates and pressure
decreases.
• Press OK, the out solenoid valve deactivates and pressure stabilizes.
4.4 PASSWORD
This is a three-digit code used to protect the set configuration.
• Select
SET PASSWORD
with the arrow keys and click OK. On the setting page, use the arrow keys to enter the desired value and click OK to
confirm. The system then displays the confirmation message “
PASSWORD SAVED
”.
• Select
PASSWORD
and click OK to enable/disable the function. If the password set to
ON
, it prevents access to the configuration menu.
When you press OK+ESC together to access the configuration menu, you are prompted to enter the password.
Enter the saved password. You can use the arrow keys to change the value or click OK to change the field.
If the password is set to
OFF
, it is not enabled.
If you forget the password, contact the manufacturer to obtain a password reset code.
Summary of Contents for REGTRONIC IO-Link
Page 1: ...REGTRONIC IO Link MANUALE D USO REGTRONIC IO Link USER MANUAL...
Page 15: ...15 NOTE Esempio di visualizzazione in Siemens S7 PCT...
Page 16: ...16 NOTES...
Page 30: ...30 NOTES Example of display in Siemens S7 PCT...
Page 31: ...31 NOTES...
Page 32: ...32 www metalwork eu M0030212 IT_EN IM00_01 2020 NOTES...