METAL-FACH
Heating Technology
10
Technical data of the boiler
(User | Installer)
Parameters
S.I. Unit.
Boiler model
SD DUO
BIO - 16
SD DUO
BIO - 20
SD DUO
BIO - 28
SD DUO
BIO - 34
Nominal heat output
[kw].
16
20
28
34
Boiler output range
[kw].
4,8-16
6-20
8,4-28
10,2-34
Heating surface
[m
2
]
2,33
2,62
2,85
3,10
Water capacity
[L]
78
84
90
100
Maximum operating pressure
[bar].
3
3
3
3
Maximum operating temperature
[°C]
80
80
80
80
Test pressure
[bar].
4,5
4,5
4,5
4,5
Boiler class
[-]
5
5
5
5
Boiler efficiency
[%]
≤90
≤90
≤90
≤90
Fuel tank capacity
[L]
300
300
300
300
Fuel
[-]
Wood pellets of class C in accordance with pt. 5.3
(Table 7) of PN EN 303-5:2012 standard:
(diameter: 6 ± 1 mm; 8 ± 1mm, length 3.15 ≤ L ≤ 40,
moisture content ≤ 12%, ash content ≤ 0.5%, calorific
value >17 MJ / kg)
Electrical connection
[-]
5A; ~230V; 50Hz
Electrical power consumption
[W]
300
300
300
300
Electric power consumption
(instantaneous at start-up)
[W]
1000
1000
1000
1000
Setting range of temperature controller
[°C]
60-
80 (in 1°C steps)
Required chimney draught
[Pa]
20
23
23
35
Design flow resistance ΔT [10K]
[mbar].
0,3
0,47
0,92
1,34
Design flow resistance ΔT [20K]
[mbar].
0,15
0,235
0,46
0,67
Boiler weight
[kg].
460
475
495
520
* Boiler /- 5kg.
Summary of Contents for SD DUO BIO 16
Page 1: ......
Page 2: ......
Page 13: ...METAL FACH Heating Technology 11...
Page 49: ...METAL FACH Heating Technology 47...
Page 50: ...METAL FACH Heating Technology 48...
Page 56: ...METAL FACH Heating Technology 54...
Page 58: ...METAL FACH Heating Technology 56...
Page 60: ...METAL FACH Heating Technology 58...
Page 67: ......
Page 68: ......