-58-
Errors and Problems
Control unit messages (1-XXX)
1-001 Notice: „Metal“
The metal detector has identified a metal part.
Once the metal part has been removed, each metal notification on the display must be acknowledged by
pressing “
OK
”.
1-002 Error: „Reject unit: Sensor faulty“
Sensor normal position supplies a wrong signal
Check the functions of your separation device. If operating normally, the cause of the error message could
also be a damaged initiator/sensor or a damaged initiator/sensor connection cable.
1-003 Error: „Reject unit: Separation faulty“
After separating items the separation device did not return to its normal position.
Check the functions of your separation device. If operating normally, the cause of the error message could
also be a damaged initiator/sensor or a damaged initiator/sensor connection cable.
1-004 Error: „Reject unit: Sensor faulty“
Sensor separation position supplies a wrong signal
Check the functions of your separation device. If operating normally, the cause of the error message could
also be a damaged initiator/sensor or a damaged initiator/sensor connection cable.
1-005 Error: „Reject unit: separation faulty“
The separation position of the separation device was not reached following a metal signal:
Check the functions of your separation device. If operating normally, the cause of the error message could
also be a damaged initiator/sensor or a damaged initiator/sensor connection cable.
1-006 Error: „Reject unit: separation faulty“
The separation device has not reached its separating position within the required time-period after detecting
metal.
Check the functions of your separation device. If operating normally, the cause of the error message could
also be a damaged initiator/sensor or a damaged initiator/sensor connection cable.
1-007 Error: „Reject unit: separation faulty“
The separation device has not reached its initial position within the required time-period.
Check the function of your separating device. If it works normally, the cause of the error message may also
be a damaged initiator or a damaged initiator/sensor connection cable. Check the initiator/sensor function
and, if need be, check the cable connection of the initiator/sensor.
Summary of Contents for METRON 07 C
Page 2: ......
Page 4: ...2 Index...
Page 18: ...16 Safety...
Page 34: ...32 Assembly...
Page 56: ...54 Adjustment...
Page 70: ...68 Errors and Problems...
Page 76: ...74 Technology...
Page 84: ...82 Appendix Example of an EU Declaration of Conformity...