-26-
Assembly
Electronic housing AMD 07
Spare part drawing number: XXX 0000 045 A
210
200
272
282
36
36
7
100
30
1.
Adaptor plate designs:
1a
Standard
1b
Option
1x M12 4-pin connector
D- coded ((
networking
)
2x
M20x1,5
free
2.
4 Mounting bores
5,2
3.
USB A socket, for:
- software updates
- reading out printing logs
- backing up and copying device and
product settings (USB stick)
4.
Coil connection (Sensor-Unit, M16)
5.
Optional interface:
e.g. networking,
Separate operating unit
(M12 8-pole A-coded socket)
6.
Free, 1x M25x1.5 and 2x M16x1.5
7.
Mains connection (M20 screw
connection)
8.
Socket M12 4-pole A-coded
9.
Isolation
10.
Lock (double-bit key 3 mm)
Opening and closing the electronic cabinet
Before opening the electronic cabine, you must stop the conveyor, disconnect the mains plug, check for
external voltage at the switch outputs and ensure that the device cannot be switched on again!
See chapter
Introduction
Safety
The electronic cabinet can be opened or closed
using a two-way key. Make sure that no cables
are trapped when closing the electronic cabine.
1.
Open(turn to the left))
2.
Close (turn to the right)
2
1a
1b
1
5
4
6 7 8
3
9
10
2
1
Summary of Contents for METRON 07 C
Page 2: ......
Page 4: ...2 Index...
Page 18: ...16 Safety...
Page 34: ...32 Assembly...
Page 56: ...54 Adjustment...
Page 70: ...68 Errors and Problems...
Page 76: ...74 Technology...
Page 84: ...82 Appendix Example of an EU Declaration of Conformity...