-71-
Technology
Relay 1 (switches when metal is detected)
Contacts 12, 11, 14
Potential-free changeover
Dead state: Contacts 11 and 12 closed
Contact load:
U~ 250V
Imax 3A
Relay 2 (switches when an error is detected)
Contacts 24, 21, 22
Potential-free changeover
Dead state: Contacts 21 and 22 closed
Contact load:
U~ 250V
Imax 3A
Switching inputs / switching outputs
User-specific inputs are configured via the switching inputs and user-specific outputs are configured via the
switching outputs. Depending on the application, different switching inputs / switching outputs can be
factory preset.
24V DC Switching inputs (Standard configuration)
24V DC Switch exits (Standard configuration)
Max. total current load of all inputs and outputs
≤
300mA !
I1
Initiator normal position (Ejection mechanism 1)
I2
Shaft encoder (speed measurement)
I3
Compressed air monitor ( Pressure monitoring )
I4
Trigger – light barrier (In)
I5
Initiator reject position (Separation unit 1)
I6
Separation unit 1 test
I7
Reset-callipers ( external )
I8
MD Offline
A1
Magnetic valve(Ejection mechanism)
A2
Ready (device ready, 24 V DC)
A3
free
A4
free