Troubleshooting and "first aid"
Event 33: Reference voltage error
Description
Overload / short circuit of the
reference value for the analogue
inputs.
Type
Error
Reason / Solution
o
Overload of the reference
voltage
-> Reduce load (see
specifications)
o
Sensor broken or defective
cable
-> Check sensor and cable
o
Invalid pin assignment of the
sensor connector
-> Check pin assignment
Note
After the problem has been fixed,
the Irinos-System must be
restarted.
Reported to the user /
application
Yes, can be disabled.
Stored in diagnostic
memory
Yes, can be disabled.
Event 34: 24V output error
Description
The 24V supply for the digital in-/
outputs and the analogue inputs
has been overloaded.
Type
Error
Reason / Solution
o
Load too high
Summary of Contents for Irinos IR
Page 2: ......
Page 7: ...Introduction...
Page 15: ...Safety instructions...
Page 22: ......
Page 23: ...System overview...
Page 39: ...Product descriptions...
Page 64: ......
Page 65: ...Pin assignment...
Page 92: ......
Page 93: ...Mounting Cabling...
Page 109: ...Setup...
Page 118: ...118 Irinos IR Users Manual 2015 2016 Messtechnik Sachs GmbH Germany Setup...
Page 120: ......
Page 121: ...Measurement Control via MscDll...
Page 168: ......
Page 169: ...Troubleshooting and first aid...
Page 187: ...Maintenance cleaning and disposal...
Page 190: ......
Page 191: ...Application notes...
Page 198: ......
Page 199: ...Specifications dimensions...
Page 209: ...209 Irinos IR Users Manual 2015 2016 Messtechnik Sachs GmbH Germany Specifications dimensions...
Page 210: ...210 Irinos IR Users Manual 2015 2016 Messtechnik Sachs GmbH Germany Specifications dimensions...
Page 211: ...211 Irinos IR Users Manual 2015 2016 Messtechnik Sachs GmbH Germany Specifications dimensions...
Page 212: ...212 Irinos IR Users Manual 2015 2016 Messtechnik Sachs GmbH Germany Specifications dimensions...