background image

3

(live or moving)

indicates hazardous parts

1000mm MIN

150mm MIN

indicated by the IP code.

Protection of persons and protection of equipment

by the IP codes two:

for electrical equipment is indicated

Protection provided by enclosures

objects. (see AS 1939, Clause 5)

against ingress of solid foreign

and protection of equipment

access to hazardous parts,

protection of persons against

(see AS 1939, Clause 6)

harmful ingress of water.

protection of equipment against

The second numeral indicates

X

0

1

2

3

4

5

6

X

1

2

3

4

5

6

7

8

0

(untested)

(untested)

Non-protected

Non-protected

falling vertically.

Protection against drops of water

position (in any direction)

falling vertically when the object

Protection against drops of water

Protection against spraying water

directions.

spraying water from all practicable

Protection against splashing and

directions.

jets of water from all practicable

Protection against low pressure

practicable directions.

strong jet of water from all

Protection against heavy seas or a

immersion.

Protection against temporary

than second numeral 7)

agreement, but no less severe

submersion (tests subject to

Protection against continous

than 50mm.

of equipment against objects larger

hazardous parts, and protection

against accidental access to

Protection of the back of the hand

than 12.5mm.

equipment against objects larger than

to hazardous parts, and protection of

objects larger than 2.5mm (e.g. ball bearings)

and protection of equipment against

or wires (larger than 2.5mm diameter),

Protection of persons holding tools

objects larger than 1mm. (e.g. ball bearings)

and protection of equipment against

tools or wires (larger than 1mm diameter),

Protection of persons holding small

satisfactory operation of equipment.

sufficient quantity to interfere with

Protection against entry of dust in

entry of dust.

Complete protection against

CHARACTERISTIC NUMERALS

IP

15

30

IP Rating Chart

IP RATING CHART

Summary of Contents for Merlin WeatherDrive MR555MYQ

Page 1: ...rmation DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THOROUGHLY MR555MYQ Garage Roller Door Opener Installation and Operating Instructions Owners Copy SAVE THESE INSTRUCTIONS for future referen...

Page 2: ...AVAILABLE when using the Key Lockable Feature This Merlin Unit is rated to IP34 and has a UV stabilizer added however to ensure the best operation of the opener the installer must ensure that it is pr...

Page 3: ...f water from all practicable Protection against low pressure practicable directions strong jet of water from all Protection against heavy seas or a immersion Protection against temporary than second n...

Page 4: ...h the proper operation of the safety reverse system or damage the garage door Installers must ensure that the doors are installed in a compliant manner as per AS NZS 60335 2 95 After installation ensu...

Page 5: ...m extended socket and socket wrench 4 300 mm socket extension for minimum side room installations 5 Drill and 5 5 mm drill bit 6 Philips head screwdriver 7 Marker pen 8 Rope 9 Door stand not shown DOO...

Page 6: ...Lock used to lock the engage disengage mechanisim for commercial applications 7 LEDs 1 Program DOWN and Diagnostic code indicator Number 1 2 Program UP indicator 3 Diagnostic code indicator Number 2...

Page 7: ...be installed on the opposite side of the door to where the opener is to be installed Ensure the U Bolt holding the door shaft to the door bracket is tightly secure NOTE This U Bolt must not be remove...

Page 8: ...ining the correct fastener location as shown lift the door approximately half a turn from the closed position to allow access for securing the screws The manual release mechanism enables the door to b...

Page 9: ...fety standard AS NZS 60335 2 95 An alternative exit path from the building MUST BE AVAILABLE when using the Key Lockable Feature Lock or unlock as required Insert key into Release Handle 8 mm allen ke...

Page 10: ...y support the door Mark the position of the door shaft on the right hand door bracket for reassembly purposes While the door is supported remove the right hand axle U Bolt and door mounting bracket fr...

Page 11: ...the door guides 5 Press and release the P program button to accept this setting 6 Press and hold the DN button until the door reaches the desired CLOSED position You can toggle between the UP and DN...

Page 12: ...or must reverse on contact with a 40mm obstacle placed on the floor Make necessary adjustments AUTOMATIC DRIVE Keep away from the area of the door since it may operate unexpectedly EMERGENCY RELEASE T...

Page 13: ...Timer to Close A BEEP will register for each press DN button will reduce the count if needed Press and release the P button to accept this setting To deactivate the Timer to Close Start with the door...

Page 14: ...he door fully OPEN Press and Hold both UP and DN buttons for 3 seconds The Courtesy light will flash TWICE Release both Buttons The WeatherDrive MR555MYQ has been factory set with the Control Panel bu...

Page 15: ...ilation activation mode by pressing the P and UP buttons together for 3 seconds figure 2 Release when the courtesy light flashes once 3 Press the transmitter button that you have allocated for this fe...

Page 16: ...ding for approximately 8 seconds until the courtesy light flashes twice again 2 Release the button all codes are now erased Activate the opener only when door is in full view free of obstruction and p...

Page 17: ...if possible Weak or broken springs could allow an open door to fall rapidly Property damage or serious injury could result CARE OF YOUR OPENER MAINTENANCE OR YOUR OPENER When properly installed your o...

Page 18: ...placed inside any part of the body call the 24 hour Poisons Information Centre on 13 11 26 in Australia or the 24 hour National Poisons Centre on 0800 764 766 in New Zealand or seek immediate medical...

Page 19: ...or are the springs broken Remove the obstruction or repair the door 7 Door reverses for no apparent reason and opener lights flash 10 times Check The Protector SystemTM IR Beams if you have installed...

Page 20: ...M 4 Channel remote control 4 Model E964M 4 Channel remote control 5 Model E138M 2 Channle Wireless wall button 6 Model E960M 4 Channel remote control 7 Model E940M 1 Channel visor remote control 8 Mod...

Page 21: ...65 002A1869 002A1874 002A1872 002A1864 002A1873 002A1871 Motor with gearbox clutch Sungear kit PCB assembly Transformer Clamp assembly Handle pull rope assembly Absolute Position Encoder APE Weight Ba...

Page 22: ...ected Check the door manually for balance binding or obstructions Internally the possible cause may be the motor logic board or RPM sensor Try resetting door travel limits Contact service centre 2 1 O...

Page 23: ...lete the registration form online at gomerlin com au warranty or gomerlin co nz warranty Get Connected with Visit www gomerlin com au or www gomerlin co nz for more details Additional purchase of the...

Page 24: ...d free of charge and are warranted for the remaining portion of the original warranty period This Chamberlain Limited Warranty provides benefits which are in addition to your other rights and remedies...

Reviews: