INSTALLATION

SETTING THE LIIMITS FOR RIGHT OR LEFT HAD OPERATION AND FORCE

14

the opener will operate during this procedure. Make sure the door is clear of obstruction. Ensure your hands 

are away from any moving parts before activating the door.

Travel limits set how far your door goes up and down. Your opener must also be configured for right or left hand installation. If not 

the door will rotate in the reverse direction. 

Program Buttons:

 The Control Panel diagram in section 4 identifies the Control Buttons and LED layout 

Audible Beep: 

An audible “BEEP” also occurs with each button press. This feature can be turned OFF 

Courtesy light:

 During the programming sequence, the courtesy light will flash at half strength 

NOTE: The WeatherDrive (MR555MYQ) opener is factory configured for right hand installation.

Setting the Right or Left Hand Operation:

Refer to the diagrams on the right for guidance. 

Ensure the door is positioned halfway and the opener is engaged 

(out of manual mode). 

Turn the opener Power 

ON

, the courtesy light will turn ON.

1.  Press the “P” button for 5 seconds until LED 3 will flash, as well 

as LED 2 or LED 1 will flash. For Right Hand setting LED 2 will 

flash, and for Left Hand setting LED 1 will flash.

2.  To change to the opposite setting, simply press the “S” button, 

and the opposite LED will flash.

3.  When the correct hand setting is selected, Press and Release 

the “P” program button to accept this setting. (continue).

Setting the Door Limits:

4.  Press and hold the “UP” button until the door 

reaches the desired OPEN position (You can toggle between 

the “UP” and “DN” buttons to move the door to the correct 

position. Ensure the bottom rail stops 50 mm below the 

mechanical stops mounted to the door guides).

5.  Press and release the “P” program button to 

accept this setting.

6.  Press and hold the “DN” button until the door reaches the 

desired CLOSED position (You can toggle between the UP and 

DN buttons to move the door to the correct position).

7.  Press and release the “P” program button to accept this setting. 

(LED 2 should flash to indicate you are now in Force Learn 

mode).

Setting the Force Automatically:

8.  Press and release the “UP” button. The door will travel to the 

OPEN position with LED 2 flashing.

9.  Press and release the “DN” button. The door will travel to the 

CLOSED position with LED 1 flashing. When fully closed, LED 1 

will stop flashing and the courtesy light will change to full power.

This process is now complete

Setting the Force manually: (Only perform if Limits are already 

set)

•  Start with the door fully CLOSED.
•  Press the “S” button twice to enter into force learn mode. The 

courtesy light will go to half strength, and LED 2 will flash 

quickly.

•  Press and release the “UP” button. The door will travel to the 

OPEN position, then LED 1 will flash quickly.

•  Press and release the “DN” button. The door will travel to the 

CLOSED position, then LED 1 will stop and the courtesy light 

will change to full power.

This process is now complete.

DN

DN UP

UP P

P

S

S

1

1

2

2

3

3

132A2940

DN

DN UP

UP P

P

S

S

1

1

2

2

3

3

132A2940

DN

DN UP

UP P

P

S

S

1

1

2

2

3

3

132A2940

DN

DN UP

UP P

P

S

S

1

1

2

2

3

3

132A2940

DN

DN UP

UP P

P

S

S

1

1

2

2

3

3

132A2940

DN

DN UP

UP P

P

S

S

1

1

2

2

3

3

132A2940

DN

DN UP

UP P

P

S

S

1

1

2

2

3

3

132A2940

DN

DN UP

UP P

P

S

S

1

1

2

2

3

3

132A2940

DN

DN UP

UP P

P

S

S

1

1

2

2

3

3

132A2940

1. Program

Start

2. Left/Right

Setting

3. Accept

Setting

4. Set UP

Limit

5. Accept UP

Limit

6. Set DOWN

Limit

7. Accept

DOWN
Limit

8. Learn UP

Force

9. Learn

DOWN
Force

Flash
x 2

Flash
x 2

Flash
x 2

Flash
x 2

Flash
x 2

Flash
x 2

Full
light

BEEP

BEEP

BEEP

BEEP

BEEP

BEEP

BEEP

DOWN

DOWN

UP

UP

Summary of Contents for Merlin WeatherDrive MR555MYQ

Page 1: ...rmation DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THOROUGHLY MR555MYQ Garage Roller Door Opener Installation and Operating Instructions Owners Copy SAVE THESE INSTRUCTIONS for future referen...

Page 2: ...AVAILABLE when using the Key Lockable Feature This Merlin Unit is rated to IP34 and has a UV stabilizer added however to ensure the best operation of the opener the installer must ensure that it is pr...

Page 3: ...f water from all practicable Protection against low pressure practicable directions strong jet of water from all Protection against heavy seas or a immersion Protection against temporary than second n...

Page 4: ...h the proper operation of the safety reverse system or damage the garage door Installers must ensure that the doors are installed in a compliant manner as per AS NZS 60335 2 95 After installation ensu...

Page 5: ...m extended socket and socket wrench 4 300 mm socket extension for minimum side room installations 5 Drill and 5 5 mm drill bit 6 Philips head screwdriver 7 Marker pen 8 Rope 9 Door stand not shown DOO...

Page 6: ...Lock used to lock the engage disengage mechanisim for commercial applications 7 LEDs 1 Program DOWN and Diagnostic code indicator Number 1 2 Program UP indicator 3 Diagnostic code indicator Number 2...

Page 7: ...be installed on the opposite side of the door to where the opener is to be installed Ensure the U Bolt holding the door shaft to the door bracket is tightly secure NOTE This U Bolt must not be remove...

Page 8: ...ining the correct fastener location as shown lift the door approximately half a turn from the closed position to allow access for securing the screws The manual release mechanism enables the door to b...

Page 9: ...fety standard AS NZS 60335 2 95 An alternative exit path from the building MUST BE AVAILABLE when using the Key Lockable Feature Lock or unlock as required Insert key into Release Handle 8 mm allen ke...

Page 10: ...y support the door Mark the position of the door shaft on the right hand door bracket for reassembly purposes While the door is supported remove the right hand axle U Bolt and door mounting bracket fr...

Page 11: ...the door guides 5 Press and release the P program button to accept this setting 6 Press and hold the DN button until the door reaches the desired CLOSED position You can toggle between the UP and DN...

Page 12: ...or must reverse on contact with a 40mm obstacle placed on the floor Make necessary adjustments AUTOMATIC DRIVE Keep away from the area of the door since it may operate unexpectedly EMERGENCY RELEASE T...

Page 13: ...Timer to Close A BEEP will register for each press DN button will reduce the count if needed Press and release the P button to accept this setting To deactivate the Timer to Close Start with the door...

Page 14: ...he door fully OPEN Press and Hold both UP and DN buttons for 3 seconds The Courtesy light will flash TWICE Release both Buttons The WeatherDrive MR555MYQ has been factory set with the Control Panel bu...

Page 15: ...ilation activation mode by pressing the P and UP buttons together for 3 seconds figure 2 Release when the courtesy light flashes once 3 Press the transmitter button that you have allocated for this fe...

Page 16: ...ding for approximately 8 seconds until the courtesy light flashes twice again 2 Release the button all codes are now erased Activate the opener only when door is in full view free of obstruction and p...

Page 17: ...if possible Weak or broken springs could allow an open door to fall rapidly Property damage or serious injury could result CARE OF YOUR OPENER MAINTENANCE OR YOUR OPENER When properly installed your o...

Page 18: ...placed inside any part of the body call the 24 hour Poisons Information Centre on 13 11 26 in Australia or the 24 hour National Poisons Centre on 0800 764 766 in New Zealand or seek immediate medical...

Page 19: ...or are the springs broken Remove the obstruction or repair the door 7 Door reverses for no apparent reason and opener lights flash 10 times Check The Protector SystemTM IR Beams if you have installed...

Page 20: ...M 4 Channel remote control 4 Model E964M 4 Channel remote control 5 Model E138M 2 Channle Wireless wall button 6 Model E960M 4 Channel remote control 7 Model E940M 1 Channel visor remote control 8 Mod...

Page 21: ...65 002A1869 002A1874 002A1872 002A1864 002A1873 002A1871 Motor with gearbox clutch Sungear kit PCB assembly Transformer Clamp assembly Handle pull rope assembly Absolute Position Encoder APE Weight Ba...

Page 22: ...ected Check the door manually for balance binding or obstructions Internally the possible cause may be the motor logic board or RPM sensor Try resetting door travel limits Contact service centre 2 1 O...

Page 23: ...lete the registration form online at gomerlin com au warranty or gomerlin co nz warranty Get Connected with Visit www gomerlin com au or www gomerlin co nz for more details Additional purchase of the...

Page 24: ...d free of charge and are warranted for the remaining portion of the original warranty period This Chamberlain Limited Warranty provides benefits which are in addition to your other rights and remedies...

Reviews: