![Mercury Vessel View 4 User Manual Download Page 46](http://html1.mh-extra.com/html/mercury/vessel-view-4/vessel-view-4_user-manual_1773201046.webp)
Section 3 - Screen Overview and Operation
Page 42
90-8M0120668
eng
MARCH 2016
a. Enable or disable the element feature.
60846
Enable selected
60845
Disable selected
b. Selecting disable will return throttle control to the operator. Troll cannot be activated again until the throttle is placed
in the idle position while still in gear.
c. Minimize will hide the troll data and display TROLL in the system status field. This allows the operator to display
information from other selected icons.
3. The set‑point adjustment selection field will be the default location at troll start‑up. After the operator makes adjustments to
the desired settings, use the arrow buttons to the enable/disable selection in the user‑selected data area footer.
a. Use the arrow buttons to move between the set‑point selection and the footer.
b. When the selection tab is above the footer navigation area (set‑point field), the operator only needs to use the arrow
buttons to make RPM or speed adjustments. There is no need to press enter to engage the new setting.
4. Minimize is a feature that allows the operator to use the troll feature while displaying additional data in the user‑selected
data area.
IMPORTANT: Set‑points cannot be adjusted when troll is minimized.
a. Scroller bar icon selection is limited. Items that are not accessible will be grayed out when troll is active.
b. If autopilot is active, and troll is minimized, the system status field will display TROLL.
60848