![Mercury Vessel View 4 User Manual Download Page 44](http://html1.mh-extra.com/html/mercury/vessel-view-4/vessel-view-4_user-manual_1773201044.webp)
Section 3 - Screen Overview and Operation
Page 40
90-8M0120668
eng
MARCH 2016
c. Selecting enable will return the RPM sweep to the cruise set point.
60842
d. Minimize will hide cruise data and display CRUISE in the system status field. This allows the operator to display
information from other selected icons.
3. The set‑point adjustment selection field will be the default location at cruise start‑up. After the operator makes adjustments
to the desired settings, pressing the PAGES button will move the selection tab to the enable/disable selection in the
user‑selected data area footer.
a. Use the arrow keys to move between the set‑point selections.
b. When the selection tab is outside the navigation area (set‑point field), the operator only needs to change the RPM or
speed adjustments. There is no need to press the enter button to engage the new setting.
4. Minimize is a feature that allows the operator to use the cruise feature while displaying additional data in the user‑selected
data area.
IMPORTANT: Set‑points cannot be adjusted when cruise is minimized.
a. Scroller bar icon selection is limited. Items that are not accessible will be grayed out when cruise is active.
b. If autopilot is active, and cruise is minimized, the system status field will display CRUISE.
•
Cruise data will be displayed over autopilot settings if the user selects the system status field.
•
If an autopilot pop‑up notification occurs or the operator uses the autopilot CAN trackpad, autopilot data will
automatically fill the user‑selected data area. The operator will have to minimize to hide the pop‑up data.
5. After minimize is activated, the system status field will display CRUISE.
6. When exit is selected while displaying the cruise element and the operator presses enter, the cruise feature will be
disabled. The cruise icon will be displayed next to the system status field until another icon is selected from the scroller bar.
Troll Control Mode
Troll Control
57379
The troll feature allows the operator to select a set‑point and adjust the value so that the vessel maintains a specific speed or
engine RPM.
•
Troll is RPM based, unless the vessel incorporated a Mercury Marine GPS into the control area network.
•
If the vessel has a Mercury Marine GPS, vessel speed is the default setting.
•
The operator can select either RPM set‑points or speed based set‑points. The type of troll option selection can be changed
in the
Settings
menu.
•
Use the arrow buttons to highlight the troll icon. Refer to
Scroller Bar Icons
to identify the troll icon.