background image

P 2

03TGCOR0707-V5 

Overall Dimensions:

 

Length = 2084mm 

Width = 2084mm 

Height = 2006mm 

Base Dimensions: 

Length = 1998mm 

Width = 1998mm 

Please retain product label and instructions for future reference

             

Before assembly  

please make sure you have a 

suitable base ready to erect your 

building 

 

MADE IN GREAT BRITAIN

*The Floor panel can be identified 

as being smaller than the roof panel.

9

Roof Support Bar - 44x58x1906mm QTY 1

F4458-1906mm

10

Rear Panel Frame - 28x28x1905mm QTY 1

FS2828-1905mm

11

Front Panel Frame - 28x28x1135mm QTY 1

FS2828-1135mm

12

Rear Roof Frame - 28x28x2050mm QTY 1

FS2828-2050mm

13

Front Roof Frame - 28x28x1172mm QTY 1

FS2828-1172mm

14

Panel Joint - 28x28x1806mm QTY 1

FS2828-1806mm

15

Rear Fascia - 12x95x2050mm QTY 2

S1295-2050mm

16

Front Fascia - 12x95x1212mm QTY 3

S1295-1212mm

17

Cover Trim - 12x40x1918mm QTY 4

S1240-1918mm

18

Rain Guard - 28x44x680mm QTY 2

RG2844-680mm

Rear Cover Trim - 12x60x1800mm QTY 2

S1260-1800mm

19

20

Rain Guard - 28x44x990mm QTY 1

RG2844-990mm

1

2

3

4

5

Door Panel QTY 1

AI-03COR0707DP-V4

Window Panel QTY 2

AI-03COR0707WP-V4

Rear Panel Right QTY 1

AI-03COR0707RPR-V4

Rear Panel Left QTY 1

AI-03COR0707RPL-V4

Floor QTY 1

AI-03TGCOR0707F-V4

6

7

8

Roof QTY 1

AI-03TGCOR0707R-V4

Secondary Door QTY 1

AI-03FGSD1715X475-V1

Master Door QTY 1

AI-03FGMD1715X475-V1

Building Content:

21

Barrel Bolt QTY 2

PI-07-0114

23

Butt hinge QTY 6

PI-07-0066

24

Door Handle QTY 2

PI-07-0081

25

Turn Button QTY 2

PI-07-0034

26

Press Lock QTY 1 

PI-07-0162

27

“L” Bracket QTY 2

PI-07-0012

Felt

28

Door Strip - 12 x 40 x 1740mm  QTY 2

S1240-1740MM

22

Door Strip - 12 x 40 x 996mm  QTY 1

S1240-996MM

29

30mm Screw x 38

50mm Screw x 38

60mm Screw x 21

40mm Screw x 62

Felt Tacks x 100

10mm Screw x 8

16mm Screw x 6

25mm Screw x 18

Nail Bag

35mm bolt x 4

Summary of Contents for 03TGCOR0707-V5

Page 1: ...arden building underneath large trees to prevent the tree causing damage to the building TIMBER As with all natural materials timber can be affected during various weather conditions For the duration...

Page 2: ...1212mm 17 Cover Trim 12x40x1918mm QTY 4 S1240 1918mm 18 Rain Guard 28x44x680mm QTY 2 RG2844 680mm Rear Cover Trim 12x60x1800mm QTY 2 S1260 1800mm 19 20 Rain Guard 28x44x990mm QTY 1 RG2844 990mm 1 2 3...

Page 3: ...x30mm Screws 7 Step 2 Parts needed No 23 QTY 2 No 27 QTY 1 Position press lock No 27 on the master door No 8 align with key hole and fix into position using 4x10mm screws Fit the barrel bolts No 23 to...

Page 4: ...until the roof is fitted 6x60mm Screws 2 2 1 Step 6 Parts needed No 4 QTY 1 No 14 QTY 1 Place rear panel left No 4 against the floor and the window side Fix the corners with 3x50mm screws as shown in...

Page 5: ...No 28 and 4x30mm screws per bracket as shown in the bubble diagram 8x30mm Screws 6 40mm screw Pre drill hole Step 10 Parts needed No 6 QTY 1 Place the roof panel No 6 on top of the building ensure th...

Page 6: ...s shown in diagram at the dotted lines use fascia width as a cutting guide Cut the triangle with 50mm overhang again using fascia as a guide 100x Felt Tacks 29 F r o n t Corner Corner Triangle 3 HANDL...

Page 7: ...12 Step 16 Parts needed No 12 QTY 1 No 13 QTY 1 Secure the front No 13 and rear No 12 roof framing to the underside of the roof fixing in place using 6x40mm screws 6x40mm Screws 40mm screw Pre drill...

Page 8: ...to the top and sides of the doors frames Make sure that the edges are flush with the edge of the framing Fix with 4x30mm screws per strip 12x30mm Screws Pre drill hole 30mm screw 22 21 21 22 21 It is...

Page 9: ...2 1 3 4...

Page 10: ...1 2 REGISTER FOR YOUR ANTI ROT GUARANTEE TODAY PLEASE SCAN HERE...