Tips: As signal interference sometimes occurs when the palm catches the metal sheet, the heart rate value displayed in 

the first 2-3 seconds may be inaccurate and on the high side, which is a normal phenomenon, and then the heart rate 

will return to normal measurement. Monitoring heart rate in this way is mainly helpful to determine your exercise, and 

cannot be used as a basis for disease treatment.   
Note: For an instrument equipped with a wireless heart rate receiving device for chest strap, the chest strap shall be 

properly worn first, and the heart rate signal shall be sent to the instrument within the signal range of chest strap.   

4.    Measuring heart rate recovery ability: In the unset state after stopping exercise (speed is 0), the heart rate should be 

measured by the above heart rate measurement method, pressing RECOVERY/UP key to enter the heart rate recovery 

function test, and then keeping holding hands or wearing chest strap (when this function is available) to measure the 

heart  rate.  At  this  time,  the  time  window  displays  a  1-minute  countdown,  and  the  value  in  the  heart  rate  display 

window will decrease because the heartbeat gradually returns to calm after stopping exercise, When the time is counted 

down to 0, your heart rate recovery status (F1 ~ F6) will be displayed, where F1 means the fastest heart rate recovery, 

followed by fast to slow, and F6 means the slowest. Pressing the RECOVERY/UP again to exit the heart rate recovery 

function test.   

5.    Measuring fat percentage, BMI and BMR: In the non-movement (speed is 0) state, pressing m) DYFAT key to enter the 

lipid measurement parameter setting state, first setting the individual NO. At this time, the corresponding No. value 

flashes, pressing RECOVERY/UP key, DOWN key to select the setting (1 ~ 8) up to 8 human body data. Pressing the 

MODE key to enter the weight setting, pressing the RECOVERY/UP key or the DOWN key to set the weight value, 

and so on: Setting weight KG, height CM, age YEAR and gender in turn. Pressing RESET/GO key after setting, then 

holding the heart rate sensing metal sheet with both hands, displaying the results after 6 seconds. Pressing BODYFAT 

again to exit the lipid measurement state.   
Note: (1) In the human body data setting state, if there is no operation within 10 seconds, it will automatically exit the 

setting state of lipid measurement parameters   
(2) In the process of fat measurement, if the measured body is not sensed for 10 seconds, [ER.1] will be displayed.   
 

5.    Comparison Table of Fat Content and Obesity   

Gender/age   

Relatively 

thin   

Normal   

Slightly fat   

Overweight   

Obesity   

Male /<30   

<14%   

14%~20%   

20.1%~25%   

25.1%~35%   

>35%   

Male /> 30   

<17%   

17%~23%   

23.1%~28%   

28.1%~38%   

>38%   

Female /<30   

<17%   

17%~24%   

24,1%~30%   

30.1%~40%   

>40%   

Female />30   

<20%   

20%~27%   

27.1%~33%   

33.1%~43%   

>43%   

 

6. Audio Amplification and Output [If this function is available]   

Connecting the audio input line to the output port of the audio player, and turning on the audio switch on the right side of 

this table to play the music output by the audio player.   
 

7. Battery Replacement   

When the display dims or there is no display, removing the battery door, install 2 new No. 5 with 1.5 V(AA, UM3) or No. 7 

(AAA,  UM4)  batteries  (4  batteries  with  MP3)  according  to  the  direction  of  the  positive  and  negative  electrodes  of  the 

battery and the battery model indicated in the battery box, and install it back.   

Summary of Contents for MR-526

Page 1: ...TICAL TRAINER INSTRUCTION MANUAL Email service merach com O cial Website www merach com Company Zhejiang Yulu Electronic Technology Co Ltd Address 298 Weiye Road Binjiang District Hangzhou Zhejiang Pr...

Page 2: ...MR 526 ELLIPTICAL TRAINER INSTRUCTION MANUAL...

Page 3: ...e note and follow the enclosed safety and assembly instructions carefully If you have questions please do not hesitate to contact us Support email service merach com Safety Instruction 2 3 Exploded Dr...

Page 4: ...d every 1 2 months that all connecting elements are tight fitting and are in the correct condition Replace defective components immediately and or keep the equipment out of use until repair For repair...

Page 5: ...CESSIVE TRAINING CAN CAUSE HEALTH INJURIES Please follow the advice for correct training as detailed in training instructions The load work level can be adjusted by turning the adjustment knob on the...

Page 6: ...0 18 41 89 90 91L 92 74 75 76 58 57 56 86 88 87 85 84 32 31 30 Item 99 2 Item 100 1 28 29 44R 45 42 43 46 20 48 49 50 53 64 65 67 68 69 70 63 71 72 73 77 78 79 80 81 82 83 91R 95 94 60 61 62 47 55 51...

Page 7: ...ness 55 60 degree PVC 1 19 Nylon bush A 19 38 outer ring with groove PA MnS2 2 20 Heartbeat line 650MM 2 21 Central axis 18 8 354 2MML extrusion tap on both sides M8 25 UCP 1 22 Umbrella head inner he...

Page 8: ...20 5 L black surface double bearings PB3851 1 62 Compression wheel arbor 10 42mml BK 1 63 Magnet 40 25 10MM Indication S N 10 64 Nut M6 opposite side 10 ucp 2 65 Double thread screw 6 80 denticulate...

Page 9: ...es Black 1 94 Ornament cover of front pipe KS 8007 ABS 1 95 Self tapping screw M4 5 25 BK 6 96 Fine tuning upper section The upper section is 540mm and the outgoing line is 30MM 1 97 Round head screw...

Page 10: ...ine with carriage screws 88 Screwing with an Allen wrench 99 Step 2 1 Firstly inserting the front pipe ornament cover 94 into the handlebar stand pipe 30 and then the connecting line 31 is connected w...

Page 11: ...ssembled 34R 25R on the handlebar stand pipe 30 firstly installing the position shown in the figure below then successively penetrating into the lower swing 25R with the central shaft 21 after that pu...

Page 12: ...rear end of the pedal tube 34R into the U shaped opening of the M piece 44R and then successively penetrating into the corresponding hole position with the inner hexagon screws 42 after that screwing...

Page 13: ...ossom knob 39 spring washer 38 and spring washer 37 on the screw pump 35 and tightening them up The other side can be installed as above Step 7 Locking the screws 15 the cushions 11 and the washers 14...

Page 14: ...position of the handlebar stand pipe 30 and fixing it with the line clamping plug 18 3 Removing the fixed screws 17 on the back of the electronic meter 1 in advance connecting the upper flat cable 31...

Page 15: ...13 Now your machine is ready to use Note Make sure all the screws are tightened before using...

Page 16: ...fat percentage Window A display 1 It measures the instantaneous speed showing the speed of movement and the measurement range is 0 0 99 9 km h 2 Revolutions per minute RPM measures the pedal speed sho...

Page 17: ...n the dashboard in front of the fitness equipment with silk 3 Installing the magnet base and the sensor at the designated positions of the fitness equipment and keeping parallel with the distance betw...

Page 18: ...sing m DYFAT key to enter the lipid measurement parameter setting state first setting the individual NO At this time the corresponding No value flashes pressing RECOVERY UP key DOWN key to select the...

Page 19: ...ncluded in the scope of free maintenance 2 If the goods need to be repaired this card and purchase certi cate should be attached to the designated repair center for repair 3 Maintenance fee will be ch...

Reviews: