![Mennekes AMTRON Premium E Installation Manual Download Page 52](http://html1.mh-extra.com/html/mennekes/amtron-premium-e/amtron-premium-e_installation-manual_1770860052.webp)
16
5.7 Set up three-phase device for single-phase
operation
For single-phase operation of a three-phase device (for
devices with 11 or 22 kW charging power), the potentiom-
eter at the phase sequence relay must be changed.
L1
L2
L3
1 3
N
X
X
16
15 18
f
Connect the device to single phase.
To do this, use the terminals L1, N and PE.
f
Adjust potentiometer (
1
) to position 1 using a slotted
screwdriver.
f
Tick checkbox “Monitoring Relay Wired to 1 Phase Only”
in service interface.
Î
“6.4.2 Menu “Installation Settings””
Setting
Description
1
Single-phase operation
3
Three-phase operation
1
5.8 Closing the device
f
Lift the front panel
(
1
)
upwards and secure it with the
screws
(
2
).
f
Fit the upper part of the enclosure (
3
) and secure it with
the screws (
4
)
and (
5
). Use supplied shortened Allen
key.
Fig.: 16. Closing the device
2
4
3
1
2
5