MODEL:  D-30 NAT. & L.P. 

 

Mendota Division of Johnson Gas Appliance Company, 520 E Avenue N.W. Cedar Rapids, Iowa 52405, extends this Extended Lifetime Protection and 
Limited Warranty to the original purchaser of a Mendota Gas Fireplace Insert, Serial Number, which is limited and used under normal home conditions. 
 

STANDARD WARRANTY: 

 
JOHNSON GAS APPLIANCE CO., MENDOTA DIVISION, WARRANTS THAT YOUR NEW MENDOTA GAS FIREPLACE INSERT IS FREE FROM 
MANUFACTURING AND MATERIAL DEFECTS FOR A PERIOD OF ONE YEAR FROM THE DATE OF INSTALLATION, SUBJECT TO THE 
FOLLOWING CONDITIONS AND LIMITATIONS: 
 

EXTENDED LIFETIME WARRANTY: 

 
THE HEAT EXCHANGER, THE BURNER TUBE,  AND THE COMBUSTION CHAMBER OF THE MENDOTA GAS FIREPLACE INSERT ARE 
WARRANTED FOR THE LIFETIME OF THE ORIGINAL OWNER, SUBJECT TO PROOF OF PURCHASE AND THE FOLLOWING CONDITIONS 
AND LIMITATIONS: 
 
1) 

This new Mendota Fireplace Insert must be installed and serviced by a competent, authorized service contractor.  It must be installed and 

 

operated at all  times in accordance with the installation and operating instructions furnished with the Fireplace.  All adjustments to logs, coals 

 

or burner must be made by an authorized Mendota Service person.  

 
This limited warranty does not cover the cost of service calls, the cost of labor to remove or install parts covered by this limited warranty, freight or other 
transportation expenses, which may be incurred in connection with obtaining performances under this limited warranty.  The remedy for damages as the 
result of any defects in this product which have been warranted herein is limited to replacement parts and does not include any incidental, indirect or conse-
quential damages or expenses sustained in connection with the products, including damages to property, except as provided by law. 
 
2) 

This warranty is non-transferable and is made to the original retail purchaser only and provided that the purchase was made through an authorized 
Mendota  dealer. 

 
Mendota is not responsible for any damage to or malfunction of the Insert unless caused by a defect in material or workmanship from normal home use.  
Damage caused by abuse, improper installation or operation, installation by unqualified personnel or breach of the conditions of this limited warranty will 
excuse Mendota from performance of any part of the limited warranty.   This warranty does not cover glass or log breakage.  Logs and embers are warranted 
against "burn out".  
 
Mendota has the right to investigate and inspect the exact original fireplace and entire installation without any alteration or tampering, in the event a claim is 
made, to determine whether  the claimed damage or malfunction was caused by abuse, improper installation or other cause outside this warranty.  Mendota is 
not responsible for any repairs or material purchases that have not received prior written approval from Mendota. 
 
NOTE:  Minor warping of certain parts or discoloration is normal and is not a defect covered by this limited warranty.  Major warping of parts can be caused 
by over-firing of your Mendota Fireplace Insert.  Over-firing above rated nameplate specifications is contrary to the manufacturer's instructions and will void 
this warranty. 
 
This warranty may not be extended by our representatives in any manner.  The company neither assumes, nor authorizes any third party to assume, on its 
behalf, any other liabilities with respect to the sale of this Mendota product. 
 
3) 

Mendota may at its discretion, fully discharge all obligations of this warranty by refunding the wholesale price of the defective part(s). 

 
4) 

All other warranties - expressed or implied - with respect to the product, its components and accessories, or any obligation/liabilities on the part 

 

of the company are hereby expressly excluded.  Products made by other manufacturers, sold with the Fireplace or thereafter, are not covered by 

 

this limited warranty..  The use of unauthorized components will make this warranty null and void. 

 
This warranty shall be effective only if the original purchaser of the Mendota appliance is registered with Mendota Division within thirty (30) days of the 
date of purchase.  This warranty with its conditions and limitations shall be the only procedure for obtaining any rights against the manufacturer and express-
es the sole obligation and responsibilities of the manufacturer which are offered to the original purchaser and accepted upon purchase of the appliance. 
 
Mendota Division, reserves the right to make changes at any time without notice, in design, material, specifications, prices and the right to discontinue styles 
and products. 
 
Some states do not allow the exclusions of limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the 
above limitation or exclusion may not apply to you.  This warranty gives you specific legal rights and you may also have other rights, which vary from state 
to state.  

Summary of Contents for SEABROOK D-30

Page 1: ...lumer d appareil 2 Ne touchez aucun interrupteur Ne pas vous servir des t l phones se trouvant dans le batiment ou vous vous trouvez 3 Evacuez la pi ce le b timent ou la zone 4 Appelez imm diatement v...

Page 2: ...ERS CO LINEAR 4 DIAMETER EXHAUST 4 DIAMETER INLET or CO AXIAL 4 DIAMETER EXHAUST 6 DIAMETER INLET TOTAL WEIGHT 175 SAFETY AGA CERTIFIED PILOT GENERATOR MILLIVOLT SYSTEM ACTIVATED WITH SWITCH REMOTE CO...

Page 3: ...material should not be placed on or near the Insert Mendota Inserts are designed for installation only in vented non combustible fireplaces Any fireplace in which an Insert is to be installed MUST be...

Page 4: ...will usually heat a large area of your home if situated to maximize heat circulation NOTE The Mendota Insert is designed as a supplemental heat source It should not be used as a whole house heating sy...

Page 5: ...MIN FROM TOP TO MANTEL FRONT VIEW 30 1 4 BRASS TRIM MANTEL 85 03 00590 16 MIN CLEARANCE TO SIDEWALL TOP VIEW 7 5 8 22 1 4 13 1 4 30 7 16 HEARTH EXTENSION 16 MIN NON COMBUSTIBLE 19 22 1 8 BE ORDERED S...

Page 6: ...HEARTH EXTENSION 19 3 4 8 MAX MANTEL 16 MIN CLEARANCE TO SIDEWALL MENDOTA GAS DIRECT VENT FIREPLACE INSERT SPECIFICATIONS CLEARANCES CO AXIAL VENT ADAPTER D 30 Surround Dimensions A B Inches mm Inches...

Page 7: ...6 flue liners permanently secure damper in open position NOTE Massachusetts requires that the flue damper must be removed or permanently welded in the open position 6 If damper opening is too small fo...

Page 8: ...Inserts 1 Co Axial and 2 Co Linear NOTE THE INSERT IS DESIGNED TESTED AND LISTED FOR OPERATION ONLY WITH MENDOTA INSERT VENTING COMPONENTS AS LISTED IN FIGURES 3 4 AND DRAWING BELOW CO LINEAR VENT KIT...

Page 9: ...e flashing Measure trim and shape flashing to fit the exist ing flue liner This flashing prevents water and small animals from entering area between the chimney liner and flue liner Plan for 1 to 1 1...

Page 10: ...arger FIGURE 5 13 One installer should then return to the fireplace opening and pull the rope to guide the liner s into place through the smoke shelf and the damper opening to a point 20 508 mm above...

Page 11: ...ent boot adapter to vent cap 4 inlet flex pipe extends from vent boot adapter to existing chimney above damper area aprox 4 5 ft Tightly secure 4 flex pipes using clamps provided Seal vent cap flashin...

Page 12: ...bricks or steel washers FIGURE 7 Draft Diverter Installation 20 VENT BOOT ADAPTER INSTALLATION A Remove 2 sheet metal screws inside top of firebox at front edge B Remove exhaust baffle by dropping fro...

Page 13: ...irmly B Reinstall exhaust baffle by placing rear edge on ledge swinging front edge upward and reinstalling two 2 sheet metal screws CAUTION The exhaust baffle must be reinstalled before operation 85 0...

Page 14: ...T BAFFLE SECONDARY AIR INTAKE MAY BE ROUND OR RECTANGULAR DRAFT HOOD FRONT ACCESS PANEL NATURAL VENT B VENT SYSTEM INSTALLATION 22 The proper Insert surround can now be placed in position Assemble sur...

Page 15: ...A QUALIFIED SERVICE PERSON THE INSERT SHOULD BE INSPECTED AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING BEDDING MATERI...

Page 16: ...e and the following procedure to see if additional floor protection is required Project a line using string or a tape measure from the top of the lower grill to the edge of the raised hearth continuin...

Page 17: ...run from the supply regulator to the Insert Refer to the following table for proper gas pipe diameters PIPE LENGTH FEET SCHEDULE 40 PIPE INSIDE DIA TUBING TYPE L OUTSIDE DIA NAT L P NAT L P 0 10 1 2 1...

Page 18: ...for the Insert EXCEPTION Some codes allow 2 PSI 1 4KPA supplies to enter the residence in which case pounds to inches regulators are used The following table provides information on correct gas press...

Page 19: ...es must be maintained LIGHTING CHECK OFF LIST Be sure to check these items before final operation of the Fireplace Insert All items on Installation Check Off List must be completed Connect Rocker Swit...

Page 20: ...ON and cycle the burner on off to make certain it ignites promptly and that the flame runs smoothly around entire burner Note Logs will produce a strong acrid odor on initial contact with flames about...

Page 21: ...or logs must not block pilot flame or burner flame and to check pilot flame with millivolt meter See Pg 30 Pilot flame must register a minimum of 450 millivolts Check that flame is stable and not lift...

Page 22: ...21 LOG INSTALLATION STEP 2 LOG INSTALLATION STEP 3...

Page 23: ...22 LOG INSTALLATION STEP 4 LOG INSTALLATION STEP 5...

Page 24: ...23 LOG INSTALLATION STEP 6 LOG INSTALLATION STEP 7...

Page 25: ...24 LOG INSTALLATION STEP 8 LOG INSTALLATION STEP 9...

Page 26: ...WAIT 60 SECONDS BEFORE TURNING ON AGAIN IF BURNER DOES NOT COME ON IMMEDIATELY AFTER SECOND TRY RECHECK COMPLETE INSTALLATION OF LOGS PILOT ETC TO INSURE PROPER PILOT FLAME IMPINGEMENT ON THE THERMOP...

Page 27: ...rs are made of special high temperature rated ABS for constant high speed operation at high temperatures Blowers are equipped with long life maintenance free ball bearings that ensure quiet operation...

Page 28: ...tat 6 Disconnect wiring connection between gas valve and ON OFF switch or thermostat wires 7 Remove two sheet metal screws that hold down the burner tube weldment and remove burner 8 Remove all sheet...

Page 29: ...in gas both natural and propane to make it smell can be harmful to glass and can leave a white film deposit on the glass This deposit can be removed with cleaners such as KEL KEM Polish Plus See your...

Page 30: ...ualified person should check the air shutter opening to make certain that the shutter is set correctly at 1 8 to 1 4 open for natural gas and full open for L P gas NOTE For altitudes above 5 000 ft so...

Page 31: ...readings will establish proper thermopile Millivolt generation and assure trouble free burner operation Readings must be taken with a Pilot ONLY operating b Main Burner operating A PILOT ONLY OPERATI...

Page 32: ...extension knob SIT 05 04 00035 Pilot Assy complete 35 01 00296 TimberFire Log Set 05 04 00036 L P Pilot orifice 35 01 00240 Bag of Coal 05 07 00061 Thermopile 35 01 00239 Glowing inswool 05 07 00067...

Page 33: ...sket Discard both the black rubber gasket and spring 3 Install the new LP Pressure Regulator onto the gas valve body in the same position and orientation as the NG Pressure Regulator you removed in St...

Page 34: ...33 Figure 21 LP PRESSURE REGULATOR NG PRESSURE REGULATOR GAS VALVE BODY SCREWS...

Page 35: ...34...

Page 36: ...acturer s specifications INSTALL PROPER SIZE GAS LINES CHECK FOR GAS LEAKS Per Manual CHECK FOR CORRECT GAS PRESSURE AT MANIFOLD Per Manual a 3 5 Inches Water Column Maximum Nat Gas b 10 5 Inches Wate...

Page 37: ...36 TAPE SHUT JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N W CEDAR RAPIDS IA 52405 POSTAGE NEEDED...

Page 38: ...e limited warranty This warranty does not cover glass or log breakage Logs and embers are warranted against burn out Mendota has the right to investigate and inspect the exact original fireplace and e...

Page 39: ...Johnson Gas Appliance Company 520 E Avenue N W Cedar Rapids IA 52405 Website www johnsongas com Part 85 03 00687...

Reviews: