11
19.
Carefully slide the Insert into place in the fireplace opening. At this time, check that Insert is level and plumb
with the fireplace opening and positioned in the middle of the opening. If Insert is unsteady or needs leveling,
the unit may be leveled by "shimming" body with non-combustible bricks or steel washers.
FIGURE 7:
Draft Diverter Installation
20.
VENT BOOT ADAPTER INSTALLATION:
A. Remove 2 sheet metal screws inside top of firebox at front edge.
B. Remove exhaust baffle by dropping front edge downward and lifting rear edge off ledge.
Set aside baffle for later re-installation.
C. Reach up through firebox opening and pull vent boot adapter downward until threaded rod is visible.
NOTE: Co-Linear vent boot adapter may be rotated 360
º
as required.
FRONT
SIDE VIEW
CO-LINEAR