26
BLOWER OPERATION AND WIRING
The D-30 Mendota Gas Inserts are equipped with hot air dual blowers. A 120 volt electrical service must be
supplied for these blowers at the fireplace at the time of installation.
These specially designed Blower Kits include an automatic snap switch that automatically turns the blowers
"On" after heat up (12- 20 min.) and "Off" after the unit cools (approx. ½ hr.). A variable speed rheostat is
also included that allows the operator to fully adjust the blower hot air output.
The low profile centrifugal blowers are made of special high temperature rated ABS for constant high-speed
operation at high temperatures. Blowers are equipped with long-life, maintenance-free ball bearings that
ensure quiet operation and maximum airflow.
The blowers are ideal for owners who wish to maximize the heating capacity and efficiency of Mendota Gas
Fireplaces. The blowers greatly increase total heating capacity by forcefully moving hot air away from the
fireplace and mantel area and out into the room. The blowers increase the overall efficiency of the Mendota
units by up to 5%.
FIGURE 15
WARNING: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS.
WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. VERIFY
OPERATION AFTER SERVICING.