WALL SWITCH, REMOTE CONTROL OR THERMOSTAT OPERATION
The Insert comes with an "ON-OFF" Rocker Switch located in the lower right hand corner of the sur-
round. An optional Wall Switch, remote control or thermostat may be purchased to substitute for the
Rocker Switch. A thermostat should be placed in the same room as the fireplace, approx. 4-5 ft. off the
floor. Do Not place thermostat near the fireplace. Thermostat must be 450 to 750 Millivolt rated. An
on-off wall switch or remote control may be used if Insert is not used primarily as a supplementary heat
source. When installed in a sleeping area, a thermostat is required.
NOTE:
If thermostat is located over 25 ft. from the fireplace the pilot flame may need to be increased.
CAUTION: BURNER SHOULD LIGHT IMMEDIATELY AFTER TURNING WALL SWITCH OR THERMOSTAT
"ON". IF BURNER DOES NOT COME ON IMMEDIATELY TURN THE THERMOSTAT/WALL SWITCH OFF
AND WAIT 60 SECONDS BEFORE TURNING ON AGAIN. IF BURNER DOES NOT COME ON IMMEDIATELY
AFTER SECOND TRY RECHECK COMPLETE INSTALLATION OF LOGS, PILOT, ETC. TO INSURE PROPER
PILOT FLAME IMPINGEMENT ON THE THERMOPILE AND PROMPT BURNER IGNITION
.
NEVER TURN BURNER ON & OFF "QUICKLY" - ALWAYS WAIT 60 SECONDS!
When using remote control be sure to hold in button firmly until Insert lights. DO NOT push button and
release quickly before Insert lights. Insert should light IMMEDIATELY and then button can be re-
leased. If Insert does not light immediately release button, wait 60 seconds and repeat lighting proce-
dure.
Use two-wire, copper lead wire per chart and install as follows:
[
FIGURE 14]
NOTE: Thermostat Must Be 450-750 Millivolt Rated
CAUTION: THIS CONTROL IS A MILLIVOLT SYSTEM. NO ADDITIONAL POWER SUPPLY CAN OR SHOULD BE USED
.
RECOMMENDED MAXIMUM
LEAD LENGTH (TWO-WIRE)
WHEN USING WALL THERMOSTAT
(CP-2 SYSTEM)
WIRE SIZE MAX.
LENGTH
14 GA.
100 FT.
16 GA.
64 FT.
18 GA.
40 FT.
20 GA.
25 FT.
22 GA.
18 FT.
THERMOSTAT (STANDARD)
WALL SWITCH OR
REMOTE ON/OFF SWITCH
WALL SWITCH/ THERMOSTAT/ REMOTE WIRING DIAGRAM
THERMOCOUPLE
Summary of Contents for SEABROOK D-30
Page 22: ...21 LOG INSTALLATION STEP 2 LOG INSTALLATION STEP 3...
Page 23: ...22 LOG INSTALLATION STEP 4 LOG INSTALLATION STEP 5...
Page 24: ...23 LOG INSTALLATION STEP 6 LOG INSTALLATION STEP 7...
Page 25: ...24 LOG INSTALLATION STEP 8 LOG INSTALLATION STEP 9...
Page 34: ...33 Figure 21 LP PRESSURE REGULATOR NG PRESSURE REGULATOR GAS VALVE BODY SCREWS...
Page 35: ...34...