INSTALLATION INSTRUCTIONS
4.1
INSTALLATION CHECKLIST
The instructions provided in this chapter are arranged in the sequence of occurrences.
This installation checklist is supplied as a guide for installers to follow step by step. As you complete each step of the installation
work, check mark the completed work item in the list, below. All items in this installation checklist must be completed. When all
work is complete, fill in your name and the date this installation was completed.
❑
Unpack the Fireplace body.
❑
Open and inspect the Manual Packet.
❑
Unbolt the Fireplace body from the wooden pallet.
❑
If planning to burn LPG, perform the NG to LPG conversion work.
❑
Place Fireplace body inside Framed Chase, level and plumb fireplace body and secure to framing studs.
❑
Open the Fireplace Glass Door.
❑
Measure chimney Length required.
❑
Install Vent System.
❑
Sealant is not required at vent joints.
Do not use silicone sealants in vent connection joints anywhere
.
❑
Adjust exhaust damper to match vertical chimney length. See 4.13.12 Vent Damper Adjustments
❑
Co-axial vent rigid pipe, wall vent cap or roof vent cap is installed by a Mendota approved
serviceperson in accordance with instructions.
❑
All joints are secured, "twist-locked" and leak-proof.
❑
Horizontal or vertical vent cap is installed "right-side-up" and tightly sealed to structure per
instructions.
❑
Proper exterior and interior clearances for vent systems and locations for wall vent cap/roof vent cap
are maintained.
❑
Correct gas pressure, proper size gas lines and gas leaks are checked.
❑
120 V electrical service and gas supply is installed in accordance with instructions and local and
national codes.
❑
Telescoping sections are not separated. They were used as complete assemblies.
❑
Connect Gas Supply to the Fireplace. Verify that gas pressures are proper and perform a complete leak test of all field
installed gas joints and factory installed gas train joints using a gas sniffer.
❑
Verify orifice sizes.
❑
Verify gas input rates.
❑
Connect Electrical Supply to the Fireplace. See
3.3.2.1 AC Power Connection Option
.
❑
Install firebox inner liner kit. Follow instruction supplied with the Liner Kit.
❑
Install log set, coals and inswool media.
❑
Install Glass door and assure that it is in proper closed position and centered in firebox opening.
❑
Test fire Fireplace.
❑
Teach consumer how to use remote control and all functions of this Fireplace
❑
Complete warranty registration at
http://mendotahearth.com/gas-fireplace-and-stove-registration.php
This installation was performed and completed by:
Date:
Summary of Contents for CHELSEA M-27
Page 2: ...85 03 01120 M27 Page 2 HOMEOWNER NOTES ...
Page 16: ...85 03 01120 M27 Page 16 Figure 3 8 Figure 3 7 ...
Page 35: ...85 03 01120 M27 Page 35 Approved Vent Systems ...
Page 62: ...85 03 01120 M27 Page 62 ...
Page 64: ...85 03 01120 M27 Page 64 ...
Page 65: ...85 03 01120 M27 Page 65 VERTICAL THROUGH THE ROOF VENTING USING THREE 900 ELBOWS ...
Page 69: ...85 03 01120 M27 Page 69 ...
Page 70: ...85 03 01120 M27 Page 70 ...
Page 71: ...85 03 01120 M27 Page 71 ...
Page 72: ...85 03 01120 M27 Page 72 ...
Page 73: ...85 03 01120 M27 Page 73 ...
Page 74: ...85 03 01120 M27 Page 74 ...
Page 103: ......