FRAMING DEPTH and FINISHING MATERIAL THICKNESS
The nominal framing depth for this fireplace is 14 inches. except for a corner installation and for installations that use solid
Granite or Marble
slabs as fascia materials. The framing depth may be left at 14” deep or reduced based on the finishing
material thickness.
Finish
Material
Thickness
Max.
Framing
Depth
½”
13 ½”
¾”
13 ¼”
1”
13”
1 ¼”
12 ¾”
1 ½”
12 ½”
1 ¾”
12 ¼”
2”
12”
Figure 3-20 FRAMING DEPTH/ FINISHING MATERIAL THICKNESS