1-833-454-0864
7
LP CYLINDER FILLING
SAFETY HOSE AND REGULATOR
•
Use only licensed and experienced dealers.
•
Ensure that the dealer checks and tests the tank for leaks after filling.
•
LP dealer must purge new cylinder before filling.
•
Dealer should NEVER fill LP cylinder more than 80% of LP cylinder volume. Volume of propane in cylinder will
vary by temperature.
•
Do not release liquid propane (LP) gas into the atmosphere. This is a hazardous practice.
•
To remove gas from LP cylinder, contact an LP dealer or call a local fire department
for assistance.
Your griddle is designed to operate on LP gas at a pressure of 2.74Kpa (11”
water column). A regulator preset to this pressure is supplied with your Griddle.
SAFETY FEATURES
of QCC-1 Quick Closing Coupling.
All models are designed to be used with an LP gas cylinder equipped with the
new QCC-1 Quick Closing Coupling system.
The QCC-1 System Incorporates
SAFETY FEATURES
required by the
Canadian Standards Steering Committee.
1. Gas will not flow until a positive connection has been made.
2.
A thermal element will shut off the flow of gas between 240 degrees F and
300 degrees F. This may result in a melted regulator hose.
3. When activated, a Flow Limiting Device will limit the flow of gas to 10 cubic feet per hour.
Connecting Regulator to the LP Cylinder
1. Turn all control knobs to the “
OFF
” position.
2. Turn LP cylinder “
OFF
” by turning hand-wheel clockwise to a full stop.
3. Remove the protective cap from LP cylinder valve. Always use cap and strap
supplied with valve.
4.
Hold regulator and insert nipple into LP cylinder valve. Hand tighten the
coupling nut. Hold the regulator in a straight line with LP cylinder valve so as
not to cross-thread the connection.
5.
Turn the coupling nut clockwise and tighten to a full stop. The regulator will
seal on the back-check feature in the LP cylinder valve, resulting in some
resistance.
WARNING
If the above instructions are not completely adhered to, it could cause a fire/explosion, resulting in death or
serious Injury, or property damage.
CAUTION
A frosty regulator indicates gas overfill. Immediately close LP cylinder valve and call local LP gas dealer for
assistance.
Nipple has to be centered
into the LP cylinder valve.
Regulator
Heat sensitive hand wheel
Nipple with flow limiting device
Hold coupling nut
and regulator as
shown for proper
connection to
LP cylinder valve.
Shut off valve
Check
valve
Summary of Contents for G70302
Page 22: ...1 833 454 0864 22...
Page 27: ...ASSEMBLY INSTRUCTIONS 1 833 454 0864 27 3 4 D4 D1 D5 x6 x2 B B B x4 C C C B D10 D10 D1 D1 D11...
Page 28: ...ASSEMBLY INSTRUCTIONS 1 833 454 0864 28 5 x6 B D4 D1 D6 D5 B B...
Page 29: ...ASSEMBLY INSTRUCTIONS 1 833 454 0864 29 6 7 x3 G D1 x4 C C C G D8 D8 D8 D8 D1 D9 D9...
Page 30: ...ASSEMBLY INSTRUCTIONS 1 833 454 0864 30 9 8 x4 B B B B B D4 D6 D18 D5 Remove the wrap...
Page 31: ...ASSEMBLY INSTRUCTIONS 1 833 454 0864 31 10 11 x4 B B D4 B1 D5 Remove the wrap...
Page 32: ...ASSEMBLY INSTRUCTIONS 1 833 454 0864 32 12 13 x3 C C x2 B B B D18 D18 B17 B17 B8...
Page 33: ...ASSEMBLY INSTRUCTIONS 1 833 454 0864 33 14 X2 x8 x4 C C C C C D D C5 C3 C4...
Page 34: ...ASSEMBLY INSTRUCTIONS 1 833 454 0864 34 15 x2 B B B A1 A2 B1 D A N G E R HEAVY LIFT WITH CARE...
Page 35: ...ASSEMBLY INSTRUCTIONS 1 833 454 0864 35 16 1ST 2ND x4 E D12 D13 D14 D14 E E E E...