![background image](http://html1.mh-extra.com/html/melec/db-2310-b32/db-2310-b32_instruction-manual_1767051024.webp)
Instructions Manual
〔DC input Connector〕
〈Crimping〉
〈Connection〉
〈Insertion〉〈Wiring〉
Contact
DC
J2
Power Supply
●Do not power ON/OFF by the relay etc. in the output side of the DC power supply.
〔Motor output Connector〕
〈Crimping〉
〈Connection〉〈Insertion〉
Housing
〈Wiring〉
Leads of the motor
J3
for J3
Contact
● Color indications for leads of the motor indicate motor of bipolar winding of
the TAMAGAWA SEIKI CO.,LTD..
Color indications for leads of the motor () indicate motor of unipolar winding
of the ORIENTAL MOTOR CO.,LTD..
● Do not use the A and B COM leads of the motor of unipolar winding , and insulate
them separately.
6-4.Inputting Power
Breakage of the machine or injury is
apprehended due to unexpected behavior of
the motor. Maintain the state where
emergency stop is enabled at any time.
(1) Input the DC power supply in the cable that connected to No.1 and No. 2
terminals of J2.
A
1
1
B
B
4
4
Motor
A
2
2
3
3
DB-2310/B32
0V
DC+24V
2
1
Housing
for J2
DC+
2
1
DC-
0V(GND)
DC+24V
DB-2310/B32
5
6
6
(N.C)
(N.C)
5
CAUTION
(0.3mm
2
or more)
(0.3mm
2
or more)
(0.3mm
2
or more)
Red
Blue
Yellow
White
(Yellow)
(White)
(Blue)
(Red
(Green)
(Black)
N.C Insulation processing
N.C Insulation processing
A COM
B COM
-24-