Instructions Manual
6-2.Connecting Signal I/O Connector(J1)
The following items are required:
●Housing for J1 (51103-0800:Molex)
One unit (accessory)
●Contact for J1 (50351-8100:Molex)
6 contacts (accessories)
●Manually operated crimping tool
One unit
for AWG28-22(57295-5000:Molex)
(1) Crimp the contact to the cable used for wiring.
(2) Insert the contact into the housing.
Make sure that the housing No. and the connector No. on the main frame are
matched before inserting the contacts.
(3) Connect the housings to the connectors on the main frame.
●The contacts for J1 are 6 pieces.
●When inserting, keep pushing J1 housing into the connectors until it is locked.
Also, check if the contacts are not displaced from the housing.
●In wiring, isolate the J1 signal lines from equipment that may be
a source of noise, the power line and the motor line.
(Surface on which the contacts are inserted)
Housing for J1
〈Crimping〉
〈Wiring〉 〈Insertion〉
〈Connection〉
User
Contact
DB-2310/B32
Controller
(0.15mm
2
or more)
J1
CWP
CWP
CCWP
CCWP
+COM
M.F
1
2
3
4
M.F-
CW+
CW-
CCW+
CCW-
(N.C)
(N.C)
1
2
3
4
5
6
7
M.F+
Housing
for J1
Drive pulse input
Drive pulse input
Motor excitation
stop input
8
5
6
7
8
-22-