ADB-5F41EL
Instructions Manual
10.Specifications
R1
10-1.General Specifications
DC+24V
*1 (Ripple voltage P-P 2.0V or less)
● Rated input current 〔DRIVE I.SEL ⇒ D1=ON set up〕
at DRIVE
DC+24V: 2.1A
*2
● Rated input current 〔HOLD I.SEL ⇒ H1=OFF set up〕
at HOLD
DC+24V: 0.3A
●Drive pulse input
DRIVE I.SEL OFF:0.75A/phase(typical)
DRIVE I.SEL ON :1.40A/phase(typical)
●Motor excitation
HOLD I.SEL OFF:Approx. 40% of DRIVE CURRENT
stop input
HOLD I.SEL ON :Approx. 50% of DRIVE CURRENT
●Drive pulse input
(CW,CCW)
Photo-coupler input
●Alarm clear signal input
(ACLR)
Photo-coupler input
●Extend functions signal
(IN)
Photo-coupler input
●Encoder signal input
Photo-coupler input
●Alarm signal output
(ALM)
O/C output
●Feature expansion signal output
(OUT)
O/C output
●Step angle selection
(STEP SEL)
●DRIVE CURRENT selection
(DRIVE I.SEL)
●HOLD CURRENT selection
(HOLD I.SEL)
●Extend functions selection
(OP SEL)
Indoor (Exposure to direct sun is not allowed.)
DC500V 100MΩ or more
*1
Input voltage range is DC+24V±10%.
*2
Use a power supply that provides sufficient input current.
(A phase,B
phase,Z phase)
Exterior
Dimensions
H
77 ×
W
85 ×
D
28
(mm)
Weight
0.1kg
●Overheat alarm
Up to 1000m above sea level
DC connector - signal connector - Frame
(Each other)
Storing
Humidity
80%RH or less
(No condensation allowed.)
Altitude
Atmosphere
Withstanding
Vibration
No abnormality should be found after a vibration test
at 10~55Hz, 0.15mm P-P
Insulation
resistance
Without any explosive, corrosive or inflammable gas, oil mist,
or dust.
-10℃ ~ +55℃
(No freezing allowed.)
(ALM LED)
Operating
Ambient
Temperature
0℃ ~ +40℃
(No freezing allowed.)
Operating
Ambient
Humidity
80%RH or less
(No condensation allowed.)
Storing
Temperature
Supply Power
Motor output
current
Input Signal
Output Signal
Overheat alarm
Functions of
Operating
Sections
-28-