Instructions Manual
4-2.Setting HOLD CURRENT SELECT switch
A high setting value may cause burn on the
skin due to overheating of the motor.
Do not select a high value beyond the
required.
DRIVE CURRENT is set up with the HOLD I.SEL switch.
The ratio of HOLD CURRENT to DRIVE CURRENT can be selected.
(1) Set the HOLD I.SEL switch No. to the ratio of HOLD CURRENT to
DRIVE CURRENT required.
● Ratio of HOLD CURRENT
HOLD CURRENT
DRIVE CURRENT
(Factory setting)
● HOLD CURRENT changes relative to DRIVE CURRENT setting.
● The greater the ratio of HOLD CURRENT grows, the more heat the motor
generates when is on holding-state.
4-3.Setting DRIVE CURRENT SELECT switch
Erroneous setting may cause motor
deterioration or damage and burn on the
skin due to overheating of the motor.
Ensure correct setting.
DRIVE CURRENT is set up with the DRIVE I.SEL switch.
The DRIVE CURRENT can be selected from two different
types of DRIVE CURRENT.
(1)
Set the DRIVE CURRENT required by the RIVE I.SEL switch [D1].
● Relationship between the DRIVE I.SEL switch and DRIVE CURRENT.
(Factory setting)
=
×
100
DRIVE I.SEL switch
DRIVE CURRENT
D1
Approx. 40%
Ratio of HOLD CURRENT(%)
ON
1.4A/phase moter
OFF
0.75A/phase moter
HOLD I.SEL switch
Ratio of HOLD
CURRENT (%)
H1
ON
Approx. 50%
OFF
注意
CAUTION
CAUTION
-14-