ADB-5F41EL
Instructions Manual
(5) Alarm signal output (ALM)
① Output current
a. I
C
≦6mA, V
CE
<2V
b. I
C
≦2mA, V
CE(sat)
≦0.6V
V
CEO
≦30V
● Upon detection of the step-out and OFF the
coupler output of the alarm signal. The ALM LED flashes.
(0.5-second intervals)
● During the alarm signal output is, it makes the motor in HOLD state.
Drive pulse will not be accepted.
(6) Alarm clear signal input (ACLR)
① Operating current range : 2.6mA~19.5mA
The photo-coupler turns on with
inter-terminal voltage of 4.5 V~26.4 V.
(Photo-coupler diode V
F
≒ 1.1 V)
● When you enter the alarm clear signal to shut off the excitation current
of the motor, and returns the internal process for the step-out to the
initial state.
● When you release the input of the alarm clear signal, it will be canceled
the alarm output signal. (Photo-coupler ON), and I will output the
excitation current to the motor.
② Timing chart
ACLR
ALM
Photo-coupler OFF
Photo-coupler ON
t1≦5ms
(t1:Time required for the motor excitation current to be shut off.)
t2≦100ms
(t2:Time required for the motor to be enabled.)
Motor
excitation
Excitation ON
HOLD state
Excitation OFF
t1
t2
9
10
ALM
R.GND
ADB-5F41EL
(J1)
Photo-coupler
11
12
ACLR+
ACLR-
(J1)
Photo-coupler
1.3kΩ
ADB-5F41EL
-32-