6.Connection
6-1.Overview of Connection Configuration
●Connect only one motor to one driver.
●Use twisted pair wire for the CW/CCW input signal line.
●Provide shielding for the signal line where considerable noise is generated.
●Use the wire material of the characteristic that is difficult to burn.
●Provide shielding for the motor line if it generates significant noise.
●For the driver's power supply, use a DC power supply with reinforced insulation
on its primary and secondary sides.
〔Example configuration〕
The metallic enclosure and shielded wires work to shield noise.
User
Controller
ADB-5F41EL
Grounding
Grounding
Motor
Grounding
Shield
Metal Encloseure
Metal Encloseure
Metal Encloseure
Shield
User
Controller
ADB-5F41EL
J1
CW+
CW-
CCW+
CCW-
6
CWP
(IN-)
(IN+)
CCWP
3
4
5
2
1
CWP
CCWP
Twisted pair wire
7
8
(OUT-)
(OUT+)
DC Power Supply
DC+24V
0V(GND)
(+COM)
( IN )
2
1
4
3
J3
Motor
J2
2
1
DC+
DC-
5
10
9
11
12
ALM
R.GND
+COM
ACLR
ALM
R.GND
ACLR+
ACLR-
( OUT )
(R.GND)
J4
6
3
4
5
2
1
7
8
9
A
A
B
B
Z
Z
+5V
GND
SHIELD
Encoder
-18-