19. Color change to move the needle case to needle #1.
20. Using a 3mm Allen wrench, loosen and remove the three (3) screws securing the right side cover
as shown in the image.
•
Note: The screw in the front of the cover is slightly longer than the two (2) rear screws. Ensure
that you use the same screws for the original position later in this procedure.
21. Remove the right side cover from the machine.
22.
Using a small oiler bottle, place twenty five (25) drops of sewing machine oil into the oiling port as
shown in the image.
•
Note: You may need to add a few drops and wait before adding more to prevent the oiling port
from overflowing.
X-Cable Tension (Test)
23. Position the x-cable tension gauge (P/N 33909) on the x-cable as shown in the image.