Figure 1 - Cable Tensioner Bracket
5. Start on the left side of the machine and loosen the hex nut on the x-cable tensioning bolt slowly
and then remove it. Hold onto the cable as you do this and do not let it drop.
6. Pull the cable through the access hole to the back of the machine body, off all of the pulleys and
let it hang loose in the back.
7. Loosen the hex nut on the tensioning bolt on the right side of the machine.
8. Pull the cable through the access hole on the right side of the machine, from around each of the
pulleys, and let it hang loose on the backside off the x-drive cable spool.
9. Loosen the screw located at the center of the x-drive cable spool from the back and remove the
cable and spool from the machine.
10. If you are going to reinstall the cable later, place it in a secure area to protect it from damage. If
you damage the protective coating, the cable will fray and eventually corrode.