Function test
8.1 Display water quality and temperature of chamber preheating
______________
By repeatedly pressing the "-" button, the preheating temperature of the chamber and the conductivity of the
purified feed water used for steam generation can be displayed alternately.
8.2 Safety with automatic monitoring
______________________________________
The electronic parameter control means that all relevant parameters are constantly monitored and compared
with standard process data, so that error reports can be made immediately. If a program is completed without
problems then on its completion there is an "End" message. The print-out contains a corresponding report.
The operator of the steam sterilizer can check the progress of the program at any time by means of the values
shown on the display (or after its completion by means of the print-out).
Operation
Display message
1. Press down the "-" button to display the conductivity of the feed
water µS/cm
Release the "-" button to return to the basic display (as shown
here) or the program status
Press the "-" button repeatedly and hold down: Display shows
the pre-heating temperature of the chamber.
AI N4 : Te m p. Pre he at.
1 2 0° C
1 4 :2 7 :12
0 .0 2 bar 2 5° C
AI N6 : Conduct i vi t y
1 5 µS/c m