background image

Technician settings

Tel: +972-3-9626462

Fax: +972-3-9626620

support@meitavtec.com

ETN24-PM-HP-SUPER-BL

Owner’s manual & Technician Settings

Pg. 6

Temperature display (Set point only or room and set point)

Press the [Mode] button again – “tr” will appear on display.

Use the [+] and [-] buttons to select between:

“tr” + “OFF”

- Set point temperature only

“tr” + “ON”

- Room temperature and set point 

Note: In the room and set point option, press the [+] or [-] buttons to 

view the set point.

Backlight ON or OFF (the backlight may not be available in all models)

Press the [Mode] button again – “bL” will appear on display.

Use the [+] and [-] buttons to select between:

“ON” 

- Back light ON

“OFF”

- Backlight OFF

On/Off or Start/Stop configuration

Press the [Mode] button again – “St” will appear on display.

Use the [+] and [-] buttons to select between:

“ON” 

- Unit will remain OFF after an electrical blackout (Start/Stop)

“OFF”

- Unit will return to previous state after an electrical blackout (On/Off)

Press the [Mode] button again to return to normal display.

Freeze protection control

Cont’

In the event of extremely low indoor temperatures conditions, the Freeze 

protection function will override any existing mode and automatically switch the 

1

st

 heating stage ON (without indication to user).

When the room temperature drops below 7°C (45°F), the thermostat will switch to 

heat mode and start the first heating stage (valve).

When room temperature returns to 8°C (47°F), freeze protection will turn OFF.

Freeze protection will start when the thermostat is either ON or OFF.

Press the [Mode] button again – “FP” will appear on display.

Use the [+] and [-] buttons to select between:

“FP” + “ON”

- Enable freeze protection

“FP” + “OFF”

- Disable freeze protection

Offset for calibration of measured temperature

Press the [Mode] button again – “OFF” and “SET” will flash.

Use the [+] and [-] buttons to adjust the offset.

Range: -5…+5

°C (-9…+9°F), Default 0°C (0°F).

ON

OFF

ON

OFF

Backlight

ON

Backlight

OFF

Start/Stop

(remains off)

On/Off

(return to 

previous state)

Freeze 

protection OFF

OFF

S

ET

°C

OFF

S

ET

°F

Offset (°C)

Offset (°F)

Freeze 

protection ON

OFF

ON

Room and set 

point

Set point only

OFF

ON

°C

°F

Summary of Contents for ETN24-PM-HP-SUPER-BL

Page 1: ...ETN24 PM HP SUPER BL Owner s manual Technician Settings C F Aux ...

Page 2: ...ed Lo Tel 972 3 9626462 Fax 972 3 9626620 support meitavtec com File etn24 pm hp super_operating manual vsd ETN24 PM HP SUPER BL Owner s manual Technician Settings Pg 2 Press and hold the Fan C F button 10 sec to switch between temperature scales Temperature scale Press and hold the On Off button 10 sec to activate deactivate Economy mode Note While in Economy mode the display will alternate betwe...

Page 3: ...pull the back panel out B Line the back panel up against the wall or flat surface Install three screws as required C Make electrical connections as shown on enclosed electrical wiring diagram D Install the cove to the back panel first the two tabs on the bottom and then the top tongue Push until tight against the wall Tel 972 3 9626462 Fax 972 3 9626620 support meitavtec com ETN24 PM HP SUPER BL O...

Page 4: ...OFF External sensor S1 1 S1 3 OFF S1 2 ON ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 2 Fan speeds 1 Fan speed ON 1 2 3 4 5 6 Internal sensor External sensor ON 1 2 3 4 5 6 Compressor delay Use DIP Switch S1 4 to activate the 3 minutes compressor delay as follows Enable compressor delay S1 4 OFF Disable compressor delay S1 4 ON Note During delay the temperature scale symbol C F will flash ON 1 2 3 4 5 6 Enable ...

Page 5: ... flash Use the and buttons to adjust the set point temperature for cooling in economy mode Range 12 32 C 54 90 F Default 28 C 82 F Set point temperature for heating in economy mode Press the Mode button again Heat and Aux will flash Use the and buttons to adjust the set point temperature for heating in economy mode Range 10 30 C 50 86 F Default 30 C 86 F The Open Close time of the valve can be adj...

Page 6: ...the Mode button again to return to normal display Freeze protection control Cont In the event of extremely low indoor temperatures conditions the Freeze protection function will override any existing mode and automatically switch the 1st heating stage ON without indication to user When the room temperature drops below 7 C 45 F the thermostat will switch to heat mode and start the first heating sta...

Page 7: ...Comments Tel 972 3 9626462 Fax 972 3 9626620 support meitavtec com ETN24 PM HP SUPER BL Owner s manual Technician Settings Pg 7 ...

Page 8: ...Tel 972 3 9626462 Fax 972 3 9626620 support meitavtec com ...

Reviews: