7.1 Troubleshooting
tool
The activities listed below may only be undertaken by specialists. Other people
may cause damage to the device and injury to persons!
7.1.1
Troubleshooting
Troubleshooting is shown on the control system display.
7.1.1.1 Testing
When an impulse is issued, testing of the stop in open + closed systems and
closing edge protection is initiated.
A system cannot be tested if “ERROR TESTING” appears on the control system
display.
The cause may e.g. be:
-
light barriers not aligned or not adjusted
-
light barrier receiver cannot be deactivated due to reflections
-
light barrier transmitter not connected to test output
-
light barrier receiver is affected by an external light (e.g. sun)
-
jumper J2 or J3 set
-
closing edge protection activated or defective
-
closing edge type incorrectly configured or not connected
-
consumers connected to terminals 21 or 24 when jumpers J2 and/or J3 are
set
7.1.2
Fault rectification
Impact Rectification
Gate not in end position
Issue new command using keys or key-
operated switches etc. If nothing moves;
call Service!