4
Gate control operating manual mts2000/02
4 - 13
m
eißner gate systems
Description of product
Stop in open + closed positions 1
(light barrier, potential-free contact)
24 V / 100 mA
Supply for transmitter
terminals 17, 21
Supply for receiver
terminals 16, 17
Switching output
terminals 19, 20
Stop in open + closed positions 2
(light barrier, potential-free contact)
24 V / 100 mA
Supply for transmitter
terminals 17, 24
Supply for receiver
terminals 16, 17
Switching output
terminals 22, 23
4.7.1.5 Connection for potential-free contact
e.g. bulb
230VAC / 2 A
(at terminals 25, 26)
4.7.1.6 Connection for lights
Lights (bulb)
230VAC / 2 A
(at terminals 29 - 34)
Supply to lights
230VAC / 2 A
(at terminals 27, 28)
4.7.1.7 Connection for drive
Drive close (relay)
230VAC / 4A
(at terminals 41, 42)
Drive open (relay)
230VAC / 4A
(at terminals 40, 42)
4.7.1.8 Device
protection
Type of protection
IP65
4.7.2
Mechanical data
Dimensions W x H x D
160 mm x 250 mm x 127 mm
Weight
1800 g
Installation position
vertical
4.7.2.1 Ambient conditions
Temperature range
0° - 60°C