4
Gate control operating manual mts2000/02
4 - 5
m
eißner gate systems
Description of product
4.4 Operating
modes
4.4.1
Impulse control as sequence control
Function:
Opening and closing the gate system after activation taking the safety
equipment and if necessary the pre-warning time setting into consideration.
Details:
•
impulse sequence
•
in key
Activation
from either:
•
radio
triggers the following function: motion status of gate changes in the following se-
quence:
OPEN
STOP
CLOSED
STOP
If the gate is in its upper or lower limit position, the STOP status is jumped.
4.4.2
Impulse control, defined up - down
Function:
1.
Opening and closing the gate system after activation taking the safety equip-
ment and if necessary the pre-warning time set into consideration.
Details:
•
impulse for open
•
impulse for close
•
in / - keys
Activation
from either:
•
radio 2 commands
triggers the following function: the gate opens or closes.