Gate control operating manual mts2000/02
Description of product
4.5 Functions
4.5.1
Continuously open switch ("gatekeeper’s switch") / external clock
Any locking switch can be fitted on site as the continuously open switch. The con-
tinuously open function takes priority over all other operating functions; i.e. “live”
processes are interrupted and the gate switches into continuously open mode.
4.5.2
Weekly indexing clock
Function:
Holding the gate open and closed at defined times of the day.
Details:
The weekly indexing clock (which can be retrofitted) controls up to 8 opening-
closing cycles per day of the week. The switching times of the week days can be
programmed individually or as a group.
If the gate is opened, the traffic is control by the light functions.
When the gate is closed, the single/dual lane feedback control system is operated
by:
•
impulse inside
•
impulse outside
•
in key
Activation
from either:
•
radio
For more information, please note the operating instructions for the clock, refer to
Chapter 6.2
Note
If selected, the superordinate special operating mode of
continuously open
(clock) is undertaken in preference to programming the weekly indexing clock.
4.5.3
Halt key
A key with a make and break contact can be fitted on-site. The halt function takes
preference over all other operating functions; i.e. “live” processes are interrupted.