12 The WEB Interface
The rst value is a so-called PTP UUID, which consists mainly of the MAC address and a xed "FFFE" middle
part as follows: XX XX XX FF FE XX XX XX
Both next values correspond to PTP status as a text and a value. The following status values are possible:
SLAVE
9
MASTER
6
PASSIV
7
If the PTP status is equal to SLAVE, the maximal oset and the maximal pathdelay to a PTP Master can be
added additionally as limit threshold values. For each PTP node the following conditions are also being checked:
1. Accessibility
2. PTP Status
3. If PTP Status = SLAVE: exceeding a given maximal absolute oset value (related to the PTP Master).
4. If PTP Status = SLAVE: exceeding a given maximal pathdelay value (related to the PTP Master).
The current status conditions are forwarded to the Notication Triggers respectively via "PTP State changed"
notication. All notications are triggered only once until the state changes in the following way:
1. A node is again accessible.
2. PTP Status has changed again.
3. Oset value is below a given threshold again.
4. Pathdelay is below a given threshold again.