12.10 Conguration: PTP
Page 83
12.10.2 Option: PTP Client Monitoring
From Lantime Firmware Version 5.34m onwards
The PTP Client-Monitor can be congured via Front Panel Time Service -> PTP IEEE1588 -> Setup PTP0
IEEE1588 V2 -> PTP Settings -> PTP Parameters -> PTP Client Management (for conguration see
the chapter on User Interfaces) and via Web Interface. In the Front-Panel maximum seven nodes (PTP Clients)
can be displayed. Therefore, for a complete overview the usage of the Web Interface is advised.
By selecting the ptpmmm_0.log button more than 100 PTP nodes can be listed. The list of PTP nodes with
their current status information has the following form:
# PTP Client Management:
found 6 PTP nodes
#
#
UUID
State-Txt
-Val
Offset
Pathdelay
Alias
#-----------------------------------------------------------------------
EC4670FFFE0024CC
SLAVE
9
-0.000000015
0.000010420
alias_0
EC4670FFFE002435
MASTER
6
0.000000000
0.000000000
0050C2FFFEB717EA
SLAVE
9
0.000000146
0.000020675
alias_2
0050C2FFFED287DE
SLAVE
9
0.000000107
0.000020859
alias_3
EC4670FFFE000801
PASSIVE
7
0.000000000
0.000000000
Prior to one or more PTP nodes monitoring, a list of the PTP clients needs to be generated. The list can
be displayed and edited via Web Interface with the ptp2_client_management_list_of_uuids_0 button.
Each line corresponds to one of the PTP node being monitored. The line format correlates to the nodes
status-info in ptpmmm_0.log (see above). Therewith it is possible to copy the line with a desired PTP node
from the status-info with "Copy" and "Paste" it to the PTP client list.
#
UUID
State text
val
offset
pathdelay
Alias
0050C2FFFED287DE
Slave
9
0.000000500
0.000025000
alias_name
LANTIME M600 MRS
Date: 31st July 2014
83