10.2 Description of the graphical menu- VF- Display
Page 21
The range of values is automatically adjusted. The x-axis starts with the rst
chronological value available in the given le. The last value is not necessarily also the last value from the given
le. If more than 255 values are available then only each xth value is displayed.
A legend can be displayed by pressing the F2 button. It contains the value range, as well as the minimum
and maximum of the graphic. By pressing a F2 button for the second time the legend disappears.
09:20
09:20
+5.000us
max:+3.999us
min:-3.000us
-5.000us
+5.000us
max:+3.999us
min:-3.000us
-5.000us
The help menu appears by pressing the F1- information button in the FULL GRAPHIC MODE. It shows all
available options in this mode. Other options are only partially available from here. To end this function one has
to press ESC-, OK- or again the F2- button.
In the FULL GRAPHIC MODE the graph can be maximized or minimized with
↑
(zoom in) and
↓
(zoom
out) buttons. If the legend is currently displayed, selecting the zoom-buttons causes that the range of y-axis gets
automatically adjusted and the legend renewed. With the ESC-button one can get back to the main menu of the
graphical program where the legend is not displayed. Alternatively, a display returns back to a FULL GRAPHIC
MODE with a default value range.
The Statistic - option comes next in the graphic menu. When you select it, you can decide if the mini-
mum or the maximum value of the current statistics le shall be displayed or not.
The minimum or the maximum values are plotted in the middle of a display, as long as at least 128 values
(a half of the display length) are available. A legend is shown on the display at the same time and apart of the
minimum or maximum value also the corresponding UTC time is displayed
5
.
Display of the minimum including the legend:
Minimum: -25.000 us
UTC: 09.04.2010 01:14:59 Uhr
Minimum: -25.000 us
UTC: 09.04.2010 01:14:59 Uhr
Display of the maximum including the legend:
Maximum: -25.000 us
UTC: 09.04.2010 01:14:59 Uhr
Maximum: -25.000 us
UTC: 09.04.2010 01:14:59 Uhr
The "SCROLLING MODE" comes as last in the graphical mode
After the status mode is displayed the whole available osets are shown in a scrolling way. The
↑
or
↓
buttons
refer in the SCROLLING MODE to its scaled up or scaled down range of values of the y-axis. Each time when
selecting these two buttons the SCROLLING MODE starts again from the beginning. Pressing the OK or
←
button causes that the graphic holds on; and pressing the OK or
→
again the graph continues to scroll on. When
the mode is stopped (the value range will be displayed) one can change the y-axis value range with the
↑
(scaled
up) and
↓
(scaled down) buttons. The oset values will only be scrolled to the end of a display and again with
5
UTC: Universal Time Coordinated is the standardized world time which does not include daylight saving time change
LANTIME M600 MRS
Date: 31st July 2014
21