Page 28
10 Conguration User Interface
Set IRIG Receiver Parameters
IRIG Code: B002/B003 (DC)
IRIG Offset from UTC (+HH:MM)
+00:00
OK
IRIG Receiver State
etup IRIG Receiver
-> S
<-
F1
F1
When pressing the OK button the IRIG code can be selected with the Up/Down arrow keys. Only the codes
which are supported by the IRIG receiver will be selectable. It must be ensured that a "DC" code is selected if
the IRIG signal is connected to the DCLS input. Otherwise the correspondent Non-DC code must be selected if
an AM signal is connected to the TC-AM input.
If the connected IRIG signal does not support the Oset to UTC you have to set up this parameter as well.
28
Date: 31st July 2014
LANTIME M600 MRS