8.3
Factory setting of the A
0
value
The factory setting for the disinfection parameter for the A0 value is 60.
To set another A0 value if required, contact MEIKO Service.
8.4
Select A
0
value
The A
0
-Value can be increased up to 3000 in predefined steps for a one-time
programme run, depending on the parameterisation of the appliance. In the se-
lection menu only values are displayed that are greater than/equal to the preset
A
0
value of the programme.
600 [1200] 3000
1. Activate the selection menu by
pressing and holding a programme
key. If the programme key remains
pressed the predefined A0 values
pass through from right to left. The
value displayed centrally [ ] is the
selected value.
2. By releasing the programme key
the selected value is taken over
and the programme starts.
In addition to the described one-time increase of the A
0
value, the appliance op-
tionally offers the possibility to temporarily increase the A
0
value for several/all
appliance in a building via a central external control system, e.g. in case of a
pandemic.