Operating instructions dishwashing machine model
K-Tronic
Datei:BA-K-tronic_MIKE_9626212_EN_2005-12-01.doc
9626212
39/44
W e reserv e the right to change execution and construction !
MEIKO Maschinenbau GmbH & Co. KG, Englerstraße 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121
Service step
Maintenance
Cleaning works
Daily
At least once
quarterly
At least once
or twice a
year
but
every
1000 h
At least once
yearly
but
every
2000 h
VERY IMPORTANT:
Whenever any electrical components are disconnected and
reconnected, replaced or repaired, a safety test must be
conducted, at least on these components!!!
8. Drying
Fan
Check fan for exterior damage
Check current consumption
(
I
N
see wiring diagram)
Check fan for quiet running (bearing damage) (visual and noise check)
Check suction side grid for cleanliness
Damper register (steam or hot water)
Check damper register for cleanliness
Clean damper register with hot water
Check damper register for watertightness (heating medium)
Blowing box
Check fan system nozzles for damage
Function check
The suction side temperature must not exceed
x1
°C.
Check internal drying chamber for cleanliness
Clean internal drying chamber with hot water (remove greases and oils)
x1
see later
9. Heat recovery
Exhaust fan
Check fan for exterior damage
Check current consumption
(
I
N
see wiring diagram)
Check fan for bearing noise (damage to bearing)
Check protection grid for cleanliness
Heat exchanger
Check heat exchanger for cleanliness
Clean heat exchanger with hot water
Check heat exchanger watertightness