Operating instructions dishwashing machine model
K-Tronic
Datei:BA-K-tronic_MIKE_9626212_EN_2005-12-01.doc
9626212
37/44
W e reserv e the right to change execution and construction !
MEIKO Maschinenbau GmbH & Co. KG, Englerstraße 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121
Service step
Maintenance
Cleaning works
Daily
At least once
quarterly
At least once
or twice a
year
but
every
1000 h
At least once
yearly
but
every
2000 h
VERY IMPORTANT:
Whenever any electrical components are disconnected and
reconnected, replaced or repaired, a safety test must be
conducted, at least on these components!!!
6. Chemical Super Save System
Check motor (if present)
Check motor for exterior damage
Check current consumption
(
I
N
see wiring diagram)
Check motor for quiet running (bearing damage)
Check ventilation grid for cleanliness
Check pump (if present)
Check sliding ring seal for watertightness (external visual check)
Replace sliding ring seal
Approx. every
2 years
Approx. every 3000 h
Check pump impeller for damage
Check pump housing for damage
Check pump screen (suction side) (if present)
Check pump screen condition
Thoroughly clean fixed pump screen internally
Clean removable pump screen internally/externally
System
Check the complete system for damage and watertightness
Check nozzles for cleanliness
Check recirculation system cyclones and pipes for cleanliness
Check function and cleanliness of water by-pass.
Clean pipes
Summary of Contents for K-Tronic