Operating instructions dishwashing machine model
K-Tronic
Datei:BA-K-tronic_MIKE_9626212_EN_2005-12-01.doc
9626212
38/44
W e reserv e the right to change execution and construction !
MEIKO Maschinenbau GmbH & Co. KG, Englerstraße 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121
Service step
Maintenance
Cleaning works
Daily
At least once
quarterly
At least once
or twice a
year
but
every
1000 h
At least once
yearly
but
every
2000 h
VERY IMPORTANT:
Whenever any electrical components are disconnected and
reconnected, replaced or repaired, a safety test must be
conducted, at least on these components!!!
7. Heat pump
(
if present
)
Check motor
Check circulating pump motor for external damage
Check circulating pump current consumption (IN see wiring diagram)
Check circulating pump motor for quiet running (bearing damage)
Check circulating pump motor ventilation grid for cleanliness
Check condenser motor current consumption (IN see wiring diagram)
Check condenser motor for quiet running (bearing damage)
Check pump (if present)
Check sliding ring seal for watertightness (external visual check)
Replace sliding ring seal
ca. alle 2 Jahre
alle ca. 3000 h
Check pump impeller for damage
Check pump housing for damage
Check pump screen (suction side) (if present)
Check pump screen condition
Thoroughly clean fixed pump screen internally
Clean removable pump screen internally/externally
Heat exchanger
Check heat exchanger for cleanliness
Clean heat exchanger with hot water
Check heat exchanger watertightness
Airbox / Airbox-Plus
Check the Airbox / Airbox-Plus for cleanliness and clean if necessary.
Clean adjusting plates / drip guards.
System
Check the complete system for damage and watertightness
Check circulation pipes for cleanliness andy function. Clean pipes and
coaxial heat exchanger
Determine if a regular heat pump check is necessary. (See heat pump
Operating Instructions attached)
Summary of Contents for K-Tronic