Maximum coin credit

0 - 65,535

Maximum coin credit that can be accepted by the
changegiver

BDV only

385

Audit unit is BDV

0 - 1

0 = audit unit  not BDV type 1 = audit unit is BDV type

BDV only

386

VMC unit is BDV

0 - 1

0 = VMC unit is not BDV

  1 = VMC is BDV

BDV only

387

CPC unit is BDV

0 - 1

= CPC is not BDV

 1 = CPC unit is BDV

BDV only

388

Card revaluation

0 - 1

0 = revaluation not allowed  1 = revaluation allowed

BDV only

389

Audit unit fitted

0 - 1

0 = audit unit not fitted

  1 = audit unit fitted

BDV only

390

VMC unit fitted

0 - 1

0 = VMC unit not fitted

  1 = VMC unit fitted

BDV only

391

CPC unit fitted

0 - 1

0 = CPC unit not fitted

1 = CPC unit fitted

BDV only

392

BDV exact change
equation

0 - 1

0 =

normal operation

  1 =

use

BDV

 exact change equation

BDV only

Address

Parameter

Range

Meaning

Notes

Summary of Contents for CashFlow 520 Series

Page 1: ...low CashFlow CashF low CashFlow CashFlow CashFlo w CashFlow CashFlow CashFlow CashFlow CashFlow CashFlow CashFlow CashFlow CashFlow C ashFlow CashFlow CashFlow Ca shFlow CashFlow CashFlow Cas hFlow Ca...

Page 2: ...y form or by any means or stored in a database or retrieval system or translated into any language natural or computer without the prior written permission of MEI MEI CashFlow and the MEI device are r...

Page 3: ...aintenance Replacing a Fuse Using the Keypad Troubleshooting Using the MEI Route Alpha 250 Terminal Address Settings for the MEI Route Alpha 250 Terminal Installing Starting and Testing a Unit Product...

Page 4: ...CashFlow 520 changegiver Pocket Guide iv MEI 1996...

Page 5: ...t apply more than the voltage specified on the unit Dangerous Environments Do not operate the unit in the presence of flammable gases or fumes or after the entry of fluid into the machine Disposal of...

Page 6: ...tab of acceptor Labels showing the coin tube positions Coin storage cassette release catches Coin storage cassette Movable float indicator Label showing keypad functions and operating voltage of unit...

Page 7: ...an the unit after the entry of dirt or fluid Take care that no drops of water enter the unit during cleaning Never use solvents or abrasive creams to clean the unit These will damage the surfaces NOTE...

Page 8: ...dispenser base with a moist cloth Switch on power to the machine press the mode button twice to park the dispenser arms and replace the coin cassette Check that the two release catches snap shut You s...

Page 9: ...d lift out the cassette Press down the blue release catch above the acceptor with a small screwdriver Pull the top of the acceptor forward and downwards Unplug the exposed ribbon cable and lift out th...

Page 10: ...hinge slots reconnect the ribbon cable and press the acceptor into place Park the dispenser arms and replace the coin cassette Make sure that the release catches of the acceptor and the cassette snap...

Page 11: ...tions Function Buttons Dispense coins from tubes Park the dispenser arms Float up tubes automatically Float down tube automatically Reset tubes to pre set levels Set the vend prices Cancel the accumul...

Page 12: ...float levels Re set Tube Counts Press the buttons to force tube counts to be re set to their pre set float levels If there are not enough tube coins to meet the pre set levels coin counts remain inco...

Page 13: ...eset levels Press A to return unit to normal operation Is the unit s interface loom firmly connected Press A B C Are correct coins dispensed FLASHING Y N OFF Y Y Y Y N N N Press Mode Mode Does the yel...

Page 14: ...oin to check operation Switch the power off wait for at least 15 seconds then switch on again Check clearance is between 2 3mm and adjust if necessary Red LED stays off No power to the vending machine...

Page 15: ...LED is flashing Fault with the changegiver unit A coin has covered the top level sensors A coin has jammed in the dispenser module Fault with the audit module Coin cassette is unclipped Press A B and...

Page 16: ...econnect it if necessary Switch off the power to the machine and clean the acceptor Red LED is off but change coins are routed to the cashbox and not to the tubes Mismatch between the true coin count...

Page 17: ...heck all looms and check all fuses Replace blown fuses following the instructions in this Pocket Guide Yellow LED is flashing The changegiver is in shifted mode because the Mode button has been presse...

Page 18: ...r check and clean the acceptor Check if the accept gate opto s are blocked Refer to the Product Maintenance Handbook before attempting to clean the opto s Unit rejects one type of coin or token Coin o...

Page 19: ...g to clean the strobes or the opto s Switch off power to the machine and check separator for jams Coins are not routing correctly The level of coins in a tube is covering a top level sensor The top le...

Page 20: ...to the Product Maintenance Handbook before you attempt to service or replace the dispenser Incorrect change is dispensed Insufficient change coins are available Incorrect coin values are set If necess...

Page 21: ...first address number with a dot or a dot and dash 1 or 1 Functions can be changed only if a dash shows after the address number Press UP or DOWN slowly to display addresses one after the other Hold d...

Page 22: ...peat the last operation Terminal powers up but addresses cannot be accessed The product is not compatible with the terminal Different terminal needed or different software needed Terminal does not pow...

Page 23: ...s 5 to 25 Only when audit fitted 226 Single vend or multi vend 0 1 0 single vend 1 multi vend 227 Escrow return inhibit 0 1 0 escrow return allowed 1 escrow return inhibited Not MDB 228 Reset mode ele...

Page 24: ...mple codes 1 8 9 If you choose 9 for this address range value coins 1 and 4 will be inhibited 230 Inhibit coin coins 5 to 8 0 15 Address value the sum of the codes where Code 0 no coins inhibited Code...

Page 25: ...s where 1 2 4 tubes A B C Not MDB 237 Exact change equation ii 0 31 Value sum of codes where 1 2 4 tubes A B C Not MDB 238 Price hold 0 1 0 do not hold price 1 hold price Not MDB 239 Price display 0 1...

Page 26: ...loat down auto tube inventory 0 1 0 float down disabled 1 float down enabled 251 254 Float level for tube A B or C 0 255 Set the number of coins to be floated to in tube A B or C 261 264 Full count fo...

Page 27: ...321 332 Value of coins 1 12 0 65 535 Value of an individual coin 340 Full sensor errors on tube A B or C 0 255 Range value sum of the codes where 1 2 4 tube A B C and 128 post gate strobe error READ O...

Page 28: ...e codes where 1 coin set code error 2 acceptor initialisation error 4 HI2 hardware error 8 HI2 transmission error READ ONLY 345 Operational errors ii 0 15 Range value sum of the codes where 1 coin cas...

Page 29: ...or flags 360 Audit module VMC I D 0 65 535 Vending machine identification code AUDIT ONLY 361 Audit print out language 0 4 0 English 1 French 2 German 3 Dutch 4 Spanish Not BDV MDB 362 Audit print out...

Page 30: ...on into machine Not BDV MDB 380 Discount award 0 9999 Amount added to credit when the vended value exceeds the discount trigger BDV only 381 Discount trigger 0 9999 If the vended value exceeds this va...

Page 31: ...387 CPC unit is BDV 0 1 0 CPC is not BDV 1 CPC unit is BDV BDV only 388 Card revaluation 0 1 0 revaluation not allowed 1 revaluation allowed BDV only 389 Audit unit fitted 0 1 0 audit unit not fitted...

Page 32: ...he changegiver is the same as in the keypad window Fit the changegiver onto the locating screws in the machine 1 Ensure that the unit is level on its three keyhole mounting slots 2 Check that the righ...

Page 33: ...t the unit s coin entry cup is aligned with the machine s coin entry chute and that the coin exit chutes are lined up 4 With the power off insert ten of the largest and smallest coins to check the coi...

Page 34: ...assette or remove the unit s cassette and fill the tubes to the float levels If the cassette is difficult to remove release it and tilt it forward Push in the coin filling flap and fill tube A through...

Page 35: ...handbooks related to the product from your MEI Approved Distributor or your regional MEI sales office MEI Product Training Product training courses are available for CashFlow and other MEI products T...

Page 36: ...REGIONAL OFFICES WWW MEIGROUP COM...

Page 37: ...YOUR MEI REPRESENTATIVE...

Reviews: