CashFlow
®
520 changegiver Pocket Guide
22
,
MEI., 1996
243
Clear overpayment inhibit
0 - 1
0 = cleardown allowed
1 = cleardown inhibited
Not MDB
244
Keypad inhibit
0 - 1
0 = keypad enabled
1 = keypad disabled
Not MDB
245
Price teach inhibit
0 - 1
0 = price teach allowed
1 = price teach inhibited
Not MDB
246
Fast sense
0 - 1
0 = normal
1 = fast (electromechanical only)
Not MDB
247
Float down
(auto tube
inventory)
0 - 1
0 = float-down disabled 1 = float-down enabled
251 - 254
Float level for tube
A
,
B or C
0 - 255
Set the number of coins to be floated to in tube
A, B or C
261 - 264
Full count for tube
A, B or C
0 - 255
Set number of coins in tube that activates
full
sensor
271 - 274
Low count for tube
A, B or C
0 - 255
Set number of coins in tube that activates
low
sensor
281 - 284
Safe count for tube
A, B or C
0 - 255
Minimum
number
of coins that must be left in a tube
(this number is multiplied by two in the changer)
Address
Parameter
Range
Meaning