High value coins are
rejected and the exact
change light is on
Too few coins in the change tubes,
leaving the low-level sensors
uncovered
Unit is in No overpay mode
Re-float the coin tubes through the acceptor so that the low-
level sensors are covered.
Check Route Alpha address 242.
Coins are accepted but
no credit is given
Power loom is not inserted correctly
Strobes in the accept gate
mechanism are blocked or dirty
Coin jam in the separator module
(post gate strobes are covered)
Switch off power to the machine, and check the loom.
Refer to the Product Maintenance Handbook before
attempting to clean the strobes or the opto’s.
Switch off power to the machine, and check separator for
jams.
Coins are not routing
correctly
The level of coins in a tube is
covering a top-level sensor
The top-level sensor loom or the
separator loom is not connected
correctly
Wrong acceptor or separator is fitted
A tube is disabled
Check tube counts. If they are above the pre-set float levels
and automatic tube inventory is set, press Mode + A + C to
float-down the coins in the tubes.
Switch off the power, remove the cassette and release the
acceptor. Check that the top-level sensor and separator looms
are fitted correctly. Replace the acceptor and cassette. Switch
on power to the unit, then insert coins and check routing.
Check that the acceptor and separator are the correct versions.
Use the Route Alpha terminal to enable the tube.
Problem
Causes
Actions