background image

 Count inputs (CP1, CP2)

  2 channels  (Max. 7500Hz, 5V  to 30V pulse)

  Frequency  (Hz)

  25, 500, 1000, 2000, 5000, 7500Hz (selectable by programming)

* 72x72mm sized.
* 2x6 digits display.
* Easy to use by front panel keypad.  
* Counting up and down with a 2 channel inputs having 90° phase shift.

 

* Input frequency can be selectable.  
* Prescaler factor can be adjusted between 0.001 and 99.9999.
* 6 digits Batch Counter.
* 6 digits Total Counter.

Preset1

 may depend on P

reset2.

 

* Decimal point can be adjusted between 1. and 5. digits.    
* Sensor type can be selected as PNP, NPN or Encoder. 
* Double set-points control is made by 2 relays outputs.  
* Output can be energized continuously or just for a time interval of 0.01
   to 999.9 seconds. 
* Selectable functional reset input. 
* Input offset feature.
* Parameter access protection on 3 levels.
* Easy connection by removable screw terminal.

* Having CE mark according to European Norms.

ENDA

PRESET UP/DOWN COUNTER

OUT1

OUT2

BATCH

TOTAL

PRESET

TOTAL

RESET

SET

EC762F

  Minimum On ans Off times
  for pulses

  

f=25Hz 

20ms for 

  1ms for f=500Hz 

  

f=2kHz 

250

m

s for  

  

f=5kHz 

100

m

s for 

  

f=7,5kHz

67

m

s for 

  

=1kHz  

500

m

s for f

 INPUTS

 1/5

 OUTPUTS

 Control output (OUT1)

 Relay : 250V AC, 2A (for resistive load), NO+NC

 Control output (OUT2)

 Open collector output (S.S. OUT1): Max. 30V DC, 100mA.  
 Relay : 250V AC, 2A (for resistive load), NO+NC

 Auxiliary power supply

 Open collector output (S.S. OUT2): Max. 30V DC, 100mA.
 12V DC, Max. 50mA (without regulation)

EC762F-E-04

 .

Mechanical  30.000.000 operation; Electrical 300.000 operation

  Life expectancy for relays

    Note : Relay and S.S.OUT outputs are in synchronization . When OUT1 relay is energized S.S. OUT1 transistor goes into saturation.

               Similarly, w

hen OUT2 relay is energized S.S. OUT2 transistor goes into saturation.

ENDA EC762F UP/DOWN COUNTER

 Thank you for choosing ENDA EC762F COUNTER.

Read this document carefully before using this device. The guarantee will be expired by 
damaging of  the device if you don't attend to the directions in the user manual. Also we don't 
accept any compensations for personal injury, material damage or capital disadvantages.  

Supply Voltage

Order Code

230V AC  +10% -20%

EC762F

24V AC  ±10%

EC762F-24AC

ENVIRONMENTAL CONDITIONS

 Height

 Max. 2000m

 Ambient/storage temperature

 Max. relative humidity

0 ... +50

 

°C/-25 ... +70°C  (with no icing) 

Rated pollution degree

TECHNICAL SPECIFICATIONS 

80% up to 31

decreasing linearly  50% at 40

°C °C

According to EN 60529                Front panel :    IP60
                                                       Rear panel  :    IP20

 Do not use the device in locations subject to corrosive and flammable gases.

 Supply

 230V AC +%10 -%20, 50/60Hz or 24V AC ±%10, 50/60Hz or optional 9-30V DC SMPS module.

 Power consumption

Max. 7VA
2.5mm² screw-terminal connections

 Wiring
 Date retention 
 EMC
 Safety requirements

 EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B for the EMC standard)  

EEPROM (Min. 10 years)

 EN 61010-1: 2001 (pollution degree 2, overvoltage category II)

ELECTRICAL CHARACTERISTICS

 1/5

HOUSING

 Housing type

 Suitable for flush-panel mounting according to DIN 43 700.

 Dimensions

 W72xH72xD97mm 

 Weight

 Approx. 405g (after packing)

 Enclosure material

 Self extinguishing plastics 

 While cleaning the device, solvents (thinner, benzine, acid etc.) or 

corrosive materials 

must not be used.

 PNP: Positive reset  (5V to 30V pulse with adjustable  pulse time between 2ms and 50ms)
 NPN: GND terminal is connected to the RESET IN terminal.

 Reset input

9-30V DC SMPS module

EC762F-24DC

Reviews: